background image

 

 

2.4 QFP Soldering 

Apply the solder paste. 

Apply the proper quantity of solder paste and install the QFP on the PWB. 

Preheat SMD. 

Refer to the photo to preheat SMD.  

Soldering 

Heat the lead frame evenly. 

 
 

2.5 Washing 
 

When soldering is completed, Wash away the flux. 
Note: The machine may cause the defects such as solder balls, solder bridges.  
Please examine the conditions of soldering sufficiently. 
 
 

3. Precautions 

 

Attaching the Nozzle 

Do not press the Nozzle or pull on the edge of the Nozzle by pliers.  

Thermal Protector  

Power will automatically be off when the unit exceeds a certain temperature. Once the temperature has dropped to a safety 
level, power will automatically turn on.  

Caution-High Temperature Operation 

Do not use the SMD unit near ignitable gases, paper, or other inflammable materials. 
The nozzle air is extremely hot and can cause painful burns. Never touch the heater pipe or allow the heated air to blow 
against your skin.  

Do not disassemble the Product. 

Disconnect the plug when you don’t use the unit for a long time. 

When the power cord is connected into the power supply, the unit has a little flow of electricity, even the Power Switch is in off position. 
So then you don’t use the unit for a long time, disconnect the plug.

 

 
 

4. Warning

 

 

Warning: this tool must be placed on its stand when not in use.  
Soldering tools not in use should be stored in a dry location which is out of the reach of children.  
Return to professional for cord replacement or service. 
    A fire may result if the appliance is not used with care, therefore 
    ----be careful when using the appliance in places where there are combustible material; 
    ----do not apply to the same place for a long time; 
    ----do not use in presence of an explosive atmosphere; 
    ----be aware heat may be conducted to combustible materials that out of sight; 
    ----place the appliance on its stand after use and allow it to cool down before storage; 
    ----do not leave the appliance unattended when it is switched on. 

 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities 
or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way 
and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by 
children without supervision. 
 
 

Summary of Contents for MKC-8908

Page 1: ...MKC 8908 STAZIONE DI RILAVORAZIONE AD ARIA CALDA SMD HOT AIR SMD REWORK STATION ESTACIÓN DE LA REANUDACION DEL AIRE CALIENTE SMD Cod 495236315 Manuale User manual Manual de usuario ...

Page 2: ......

Page 3: ...ssione breve farà variare la temperatura di 1 C alla volta Una pressione lunga farà cambiare la temperatura velocemente 2 Il tasto permette di selezionare la temperatura in C o F La temperatura di default è in C 3 L unità è dotata della funzione sleep stand by automatico Quando la pompa viene posizionata sul supporto il prodotto smette di erogare calore Il display mostra SLP SLEEP Quando la pompa ...

Page 4: ...ione è connesso alla rete elettrica l unità ha un leggero flusso di corrente anche se l interruttore è spento Quindi se non viene utilizzata è meglio scollegarla dalla rete 4 Avvertenze Quando non è utilizzato questo attrezzo deve essere riposto sul suo supporto Gli utensili di saldatura non in uso devono essere depositati in un luogo asciutto lontano dalla portata dei bambini Rivolgersi a persona...

Page 5: ...mm 495236216 Diam 1 5x3mm Cod 495236224 Kit 12 ugelli per applicazioni Smd cod 495236147 6 Ugelli opzionali 7 Contenuto della confezione n 1 Unità di controllo n 1 Generatore Stilo ad aria calda cod 495236319 n 1 Supporto di sicurezza n 1 Ugello Diametro 5 0mm cod 495236316 n 1 Ugello Diametro 8 0mm cod 495236317 n 1 Ugello Diametro 12 0mm cod 495236318 Manuale ...

Page 6: ...short press the set point will change 1 C in long press the set point will change quickly and reach your target temperature 2 is the transfer button between C F the default unit is C press the button to make change between C and F 3 This item has sleep function When you put the air pump on the racket the item will stop heating and the display shows SLP means SLEEP when you pick up the air pump the...

Page 7: ...ply the unit has a little flow of electricity even the Power Switch is in off position So then you don t use the unit for a long time disconnect the plug 4 Warning Warning this tool must be placed on its stand when not in use Soldering tools not in use should be stored in a dry location which is out of the reach of children Return to professional for cord replacement or service A fire may result i...

Page 8: ...Diam 19x19mm 495236216 Diam 1 5x3mm Cod 495236224 n 12 nozzles Kit for Smd applications cod 495236147 6 Optional Spare parts Nozzles 7 Package contents n 1 Control unit n 1 hot air generator iron cod 495236319 n 1 Safety rest n 1 Nozzle diameter 5 0mm cod 495236316 n 1 Nozzle diameter 8 0mm cod 495236317 n 1 Nozzle diameter 12 0mm cod 495236318 Manual ...

Page 9: ...tura Una presión breve hará variar la temperatura de 1 C a la vez Una presión larga hará cambiar rapidamente la temperatura 2 permite de seleccionar la temperatura en C o F La nuidad por defecto es en C 3 Este producto tiene la función sleep stand by automático Cuando la bomba es posicionada sobre el soporte el producto para de erogar calor El display enseña SLP SLEEP Cuando la bomba es levantada ...

Page 10: ...e alimentación es conectado a la red eléctrica la unidad tiene un ligero flujo de corriente aunque el interruptor es apagado Luego si no es utilizada es mejor desconectarla de la red 4 Advertencias Cuando no es utilizado este utensilio tiene que ser repuesto sobre su soporte Los utensilios de soldadura no en uso tienen que ser depositados en un lugar seco lejos del alcance de los niños Dirigir a p...

Page 11: ...16 Diam 1 5x3mm Cod 495236224 Kit de 12 boquillas para aplicaciones SMD cod 495236147 6 Toberas opcionales 7 Contenido de la confección n 1 Unidad de control n 1 Generador Stilo aire caliente cod 495236319 n 1 Soporte de Seguridad n 1 Boquilla de 5 0 mm de diámetro cod 495236316 n 1 Boquilla de 8 0 mm de diámetro cod 495236317 n 1 Boquilla de 12 0 mm de diámetro cod 495236318 Manual ...

Page 12: ...sehold wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling El símbol...

Reviews: