X Rack Not Done
See Y Rack Not Done.
Y Axis Limit
The drive circuit of the Y axis motor has detected excess power, caused by a jammed Y axis motor
or beam or a malfunction of the Y axis motor or electronics. Turn the power OFF, then ON to
recover. If this error occurs more than once during a design, call your representative for assistance.
Y Command Error
This means an invalid command sequence was detected in the Y axis motor controller software
functions. Turn the power OFF, then ON. If this error occurs more than once during a design, call
your Melco representative for assistance.
Y Rack Not Done
The needle is trying to enter the cloth before the X or Y motion is complete. It is caused by a
combination of a dense fill stitch and embroidery speed. Reduce the speed to allow the needle time
to clear the fabric.
Z Command Error
An invalid "read" or "write" command sequence was detected in the Z controller software
functions. Can occur during high embroidery speed. Reduce the speed or go to the Head Timing
Menu and choose Go To Headup command. Press [START] to continue.
Z Tracking Err
This means the Z axis motor is not tracking as commanded by the Z axis controller software.
Execute the Go To Headup option in the Head Timing Menu. Exit the Head Timing Menu and press
[START]. If the message does not clear, call your Melco representative for assistance.
Z Timeout Error
Both axes were commanded to move but did not complete the move in the allowed time. To
recover, execute the Go To Headup option in the Head Timing Menu.
Repeated occurrences of this message may indicate a mechanical bind in the embroidery head.
Locate and correct the problem. If you cannot locate the problem or if this message occurs often,
call your Melco service representative.
B - 8
X Rack Not Done
Advantage 18 Operation Manual
Melco Embroidery Systems
Summary of Contents for Advantage 18
Page 6: ...Table of Contents Operation Manual iv Advantage 18 ...
Page 14: ...1 8 Start Up Messages Advantage 18 Operation Manual Melco Embroidery Systems ...
Page 92: ...C 2 Advantage 18 Operation Manual Melco Embroidery Systems ...
Page 94: ...Advantage 18 Operation Manual Melco Embroidery Systems ...
Page 96: ...Quick Reference Guide for Advantage 18 Part Number 110265 01 Rev A ...