4. Holding the hook support from the side with the adjustment screws, adjust the position of the
hook support to the requirements specified in the inspection procedure.
5. Remove the gauge while holding the position of the hook support, being careful not to scratch
the highly polished surface (this is critical to proper operation).
6. Tighten the 2 screws holding the hook support.
Figure 3 – Hook Support Adjustment
7. Verify that the gauge still slides freely between the basket and hook support.
8. You may now reinstall the needle plate and bobbin case.