109 of 271
20. If any noticeable binding occurs, repeat steps 18-20 until color changing from Needle 1 to Needle
16 and back is smooth and consistent.
21. Install the needlecase cover and access cover, and color change covers.
22. Run a short functional test using the test design AMPASSxxx with the machine in the unthread-
ed mode. Visually observe the color change functions and make sure everything was properly
installed and adjusted. It is only necessary to run the machine through all 16 needles, then the
functional test can be stopped as long as everything is correct.
23. Run test design AMTTTESTXXX to test color change functions.