162 of 271
WARNING!!
Do not attempt to disassemble the power supply unit for any reason. There are no
user serviceable components inside. Internal components in the power supply unit might still
have residual voltage (even if power is disconnected) that can cause painful electrical shock.
1. Disconnect the harness wiring from both wiring blocks on the side of the power supply.
2. Remove the four Phillips head screws (w/star) on the bottom of the power input mounting plate
that mount the power supply to the plate.
3.
Install a new power supply unit and install the screws loose at first, then tighten them to the
torque specifications when all four are installed.
Figure 1 - Bottom Wiring Block (Switch Interface Leads)
4. Attach the ring connectors of the switch interface harness to the power supply wiring blocks as
shown in Figure 1 above. Tighten the screws enough to hold them securely but do not over tight-
en them.
Figure 2 - Top Wiring Block (Wire Leads from Power Interface Harness)
5. Connect the leads of the power supply interface harness (coming from white 8 position connector
above switch) to the top wiring block on the side of the power supply as shown in Figure 2 above.
The labels shown are also marked with tags on the harness itself. The V+ and V- leads are inter-
changeable with any of the other leads having the same labeling (V+ or V-).
Power Input Switch Replacement
WARNING!!
This procedure is intended to be performed only by specially trained Melco service
technicians and personnel. Disassembly by untrained individuals will void any warranty protec-
tion and can result in personal injury or damage to the machine.
1. Disconnect the red, black and green wires from the back of the switch.