183 of 271
CAUTION!!
When disconnecting the harness DO NOT pull on the wires. Handle only the con-
nector housings. You will damage the harness if you pull on the wires themselves.
6. Disconnect the laser harness from the laser pointer assembly.
Figure 2 - Right Upper Arm Access Hole
7. From behind the upper arm, pull the laser harness through the right upper arm access hole.
8. Pull the laser harness out the right wiring channel and remove any twist-lock cable ties that bun-
dle the laser harness to adjacent harness, down to the back of the machine.
9. Remove the EMI cover from the main control board.
10. Disconnect the laser harness from the connector at J30 on the Main PCB and cut any remaining
wire ties that bundle the laser harness to adjacent harnesses.
11. From behind the right upper arm, run the harness lead that is labeled “LASER” through the right
upper arm access hole and connect it to the laser pointer assembly as shown in Figure 1.
12. Right behind the right upper arm, pull the unneeded slack out of the harness, and use a twist-lock
cable tie to bundle the laser harness to the other two adjacent harnesses that run through the
hole.
13. Run the laser harness down to the right wiring channel following the same path as the adjacent
harnesses in the channel down to the Main PCB and connect the end labeled “CONTROL PCB
LASER - J30” to the connector socket at location J30 on the Main PCB.
14. Replace the EMI Cover carefully.
15. Replace all twist-lock cable ties.
16.
Install the right upper arm front cover and tighten the screws to the torque specifications.
17. Turn the machine ON.
18. Turn the laser on and off to make sure the laser assembly and harness is working.
19. Install the covers to the machine in the reverse order that you removed them and tighten the
screws to the torque specifications.
Table of Contents