263 of 271
correctly adjust the settings described in this manual can result in unpredictable behavior of the machine
and can cause premature failure of the machine.
In most cases, it is necessary to use the prescribed procedure to measure the settings and adjustments on
the machine. Deviation from established procedure or using different methods to do the measurements
will often yield different results. In order to obtain consistent measurements, use the procedures de-
scribed in these instructions.
Use the correct tools and instructions for measurements and adjustments on the machine. The machine is
sensitive to incorrect adjustments and is easily damaged when the settings on the machine is not correct-
ly set.
These instructions are targeted to trained authorized technicians. The assumption is made that the field
technician has received full training in the use of the tools described in these instructions. Therefore, no
attempt is made to explain how to use the tools indicated or how to install them on the machine. These
instructions also assume that the technician performing these procedures is fully knowledgeable with the
machine parts and their orientations.
Needle Drive Stud to Reciprocator Fit
Measurement
1.
Needle drive stud to reciprocator fit is measured in terms of the amount of vertical free play in the
needle with the machine powered up.
2. Color change to either needle 1 or 16. Measure the vertical free play of the current needle using
a dial indicator fixture (Fixture Number 32453) to measure the distance that the needle bar travels
up and down. It should be less than 0.006” [0.15mm].
3. Color change to the next needle and measure it, and check all 16 needles.
Adjustment
There is no adjustment to the needle drive stud to reciprocator fit.
If the fit is found outside of the.006” [0.15mm] maximum specification, report this via email to the ma
-
chine manufacturer.
Hook Timing
See hook timing section in this manual.
Upper Arm to Lower Bed Alignment
Measurement
1. Measurement of the upper arm to lower bed alignment is done by measuring the average of the
needle centering front to back, starting with the “closest needle.”