The following is a list of various tension and force specifications for your machine. See the Critical
Measurements section for other machine specifications that are not listed below.
Specification
BRECO Meter Measurement
Force Gauge Measurement
X Drive Cable Tension
145 ± 5 Hz at 350±2.5 mm
between center of first and rear
pulleys measured from right side
of machine only.
10.5 ± 0.5 lbs [4.76 ± 0.23
kg] using X-Cable Tensioning
Procedure
Left and Right Y-Drive Belt
Tensions
45-50 Hz with beam to the back
at a dead stop
8.1 ± 0.3 lbs [3.67 ± 0.14
kg] using Y-Axis Timing Belt
Tensioning procedure
Y-Motor Belt Tensioning
100-120 Hz
7.5 - 9.5 lbs [3.4 - 4.3 kg] using
Y-Motor Timing Belt Tensioning
procedure
Z-Motor Belt Tensioning
72-78 Hz
6.8 ± 0.3 lbs [3.08 ± 0.14 kg]
measured using Z-Drive Belt
Tensioning procedure
X-Carriage Drag (Friction)
5.5-9.5 lbs, Disconnect motor
from control board
Y-Carriage Drag (Friction)
10-25 lbs [4.5-11 kg], Disconnect
motor from control board
The following lists the X and Y home positions attained when the “Set Home” function is initiated on the
machine.
X Home: centered within ± 0.015 inches [0.4 mm]
Y Home: carriage mounting holes positioned 7.09 ± 0.015 inches [180 ± 0.4 mm] (relative to needle
plate hole)