92 of 271
Z-Drive Belt Tensioning
This procedure can be performed by the machine operator as long as the
following procedures are followed explicitly.
This procedure requires the use of a 0-10 lb. Force Gauge and a Universal
Force Gauge Adapter, a 3mm hex wrench.
Inspection and Adjustment
1. Attach the Universal Force Gauge Adapter, PN 32498, to the 0-10 lb. Force Gauge, PN 995591-01
(screw adapter on the end of the gauge).
2. Turn the machine OFF.
3. Remove either one of the upper arm covers and the innermost back screw of the other one (re-
move screws with a 3mm hex wrench).
4. Remove the upper arm back cover (remove screws with a 3mm hex wrench).
5. Locate the z-drive belt and the z-motor mounting bracket.
6. Using a ruler (preferably metric) mark the z-motor mounting bracket 17mm (0.67”) below the top
edge of the bracket.
7. Position the gauge adapter (with gauge attached) as shown in the image below.
Table of Contents