93 of 271
The right side of the adapter should be lined up with outside edge of the motor mounting
bracket.
8. Push down on the force gauge until the top of the belt lines up with the mark on the mounting
bracket. The force should be 6.8 ± 0.3 lbs.
9. To adjust the tension of the z-drive belt, hold the idler pulley steady with one hand and loosen the
screw with a 3mm hex wrench. Turn the z-idler pulley clockwise to increase the tension (counter-
clockwise to reduce tension) and then tighten the screw to the Torque Specifications.
Measure the tension again (as specified in Steps 7 and 8) and if it is not correct, repeat step 9 until
the tension is set to the specification.
10. Reinstall the covers in the reverse order that you removed them. Tighten the screws to The torque
specifications.
11. Do a short machine functional test to verify proper z-axis timing (needle bars synchronized, with
rotary hook movement).
•
Note: If a BRECO meter is used to measure the tension, the measurement should be 72-78 Hz.