188 of 271
Thread Break Harness
The thread break harness connects the thread break sensor PCB to the Main PCB at connector socket
J29.
Replacement Parts Needed:
• harness, thread break
• twist-lock cable ties (available at most hardware stores in the electrical section)
Replacement Procedures:
1. Color change to Needle 1.
2. Remove the needle case access cover and the needle case cover.
3. Remove the right arm cover and the back screw of the left one.
CAUTION!!
Use extreme care not to drop metallic objects, tools, or other conductive material
on the Main PCB when you have the base cover removed. If you drop such objects on the Main
PCB, it can severely damage the electronics which will be very expensive to repair.
4. Remove the upper arm back cover, lower arm rear cover, and base cover.
Figure 1 - Threadbreak Harness Connected to Sensor PCB
5. Disconnect the thread break harness from the thread break sensor PCB.
6. Remove all the twist-lock cable ties that tie it to the adjacent harnesses all the way up to the front
of the thread tree base.
7. Remove the twist-lock cable tie that bundles the harnesses behind the thread tree base and pull
the thread break harness through from the back of the thread tree base.