6-6
Error Messages
Operation Manual for the EMT 10T, 10/4, and 10/4T
Melco Embroidery Systems
Not At Headup
Means you are trying to execute an X or Y move function or color change function when the
sewing head is not at Head Up. Cycle to the Head Up position with the Function Menu command
GO TO HEADUP.
Off Color Index
Means the machine tried to do a color change, or you tried to use a Head Timing function while
the color change cam was off index. Go to the Idle menu and press the
or
keys to move the color change cam on index. If this does not resolve the problem, try manually
resetting the cam.
To manually reset the cam, follow these steps:
1. Locate the Color Change Cam reset screw (it is a flat-
head screw). On the EMT 10T, it is on the left side of
the head (as you are facing the machine), behind the
needle case. On the EMT 10/4 and 10/4T it is on the
right side of head #1 (as you are facing the machine),
behind the needle case. Figure 6-1 shows the locations
on an EMT 10T. The LED and screw are in the same
locations behind head #1 on an EMT 10/4 or 10/4T.
2. There is an LED on the top of the arm that supports
the head. When this light is ON, the head is OFF
INDEX. Turn the screw until the light goes OFF.
3. Before you can perform any other functions, you must perform a GOTO HEADUP.
If the problem still exists, call your Melco representative.
Outside of Hoop
Trying to do a Trim Immediate when the needle is outside of the selected hoop limits.
Power Fail Recover Job Error
Trying to do a Power Fail Recovery when a design was not started.
Reload <design name>
An error was found when the computer was loading a design while running in Auto Send. Delete
the design and reload it from the computer. Frequent occurrences indicate a system memory prob-
lem, or a bad link in the network.
▼
▼
▲
▲
▼
▲
Figure 6-1
Screw
LED
Summary of Contents for EMT 10/4
Page 52: ...2 28 Quick Start Operation Manual for the EMT 10T 10 4 and 10 4T Melco Embroidery Systems ...
Page 108: ...6 10 Error Messages Operation Manual for the EMT 10T 10 4 and 10 4T Melco Embroidery Systems ...
Page 126: ...INDEX Operation Manual for the EMT 10T 10 4 and 10 4T ...
Page 127: ...Quick Ref erence Guide for the EMT 10T 10 4 and 10 4T 11817 Revision A ...