12616, Rev. B
14. Replacement of X-Y Carriage
35
14. Replacement of X-Y Carriage
1. Perform steps (1)-(3) in
par.13.
2. Fix the wire (C) to pulley
(A) securely by using grip
band (B) as shown in
Fig.14-1. Loosen setscrews
(D), and disconnect wire
(C) from wire pulley (E).
3. Bring the Y-carriage
(F) toward the sensor
until it touches
stopper (G) as shown
in Fig.14-2.
4. Remove setscrews
(H)(H*), and separate
the wire (I) and Y-
carriage from each
other. Fig14-2.
5. Fix the wires being
wound on the pulleys
securely by grip
bands (K) so that the
right and left wires (I)
are not loosened
from pulley (J) as shown in Fig.14-2.
6. Loosen setscrew (L*) and setscrew (L), and tilt down wire pulley (M). Fig.14-2.
FIGURE 14-1
C
D
E
H
A
B
F
FIGURE 14-2
I
J
K
H
G
M
L
L*
H*