Instructions Manual
4-3.Setting HOLD CURRENT ADJUSTMENT trimmer
R1
A high setting value may cause burn on the
skin due to overheating of the motor.
Do not select a high value beyond the
required.
HOLD CURRENT is set up with the HOLD I.ADJ trimmer.
This sets the ratio of HOLD CURRENT to DRIVE CURRENT.
The trimmer is factory-set to approx. 40%.
(1) Set the gauge of the trimmer to the required value.
●Relationship between the trimmer scales and HOLD CURRENT.
HOLD CURRENT
DRIVE CURRENT
Ratio of HOLD CURRENT
Trimmer
Scale of the trimmer
● HOLD CURRENT changes relative to DRIVE CURRENT setting.
The ratio of HOLD CURRENT of 100% represents the same as the setting for
DRIVE CURRENT.
● The greater the ratio of HOLD CURRENT grows, the more heat the motor
generates when is on holding-state.
● When the trimmer is set minimum, HOLD CURRENT is approx. 10% or less of
DRIVE CURRENT.
=
Ratio of HOLD CURRENT(%)
×100
I
100%
50%
0%
0
2
3
4
6
8
9
7
1
5
10
Factory setting
5
1 0
0
-15-