GD-5510-01
Instructions Manual
4-8.Setting PULSE INPUT TYPE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
2-pulse input method/1-pulse input method are
set up by the SPI SEL switch.
Set this switch with power OFF.
The switch is factory-set to 2-pulse input method[2P].
(1) Turn power [OFF].
(2) Set the SPI SEL [2P/1P] switch.
● When the motor is operated with two pulse signal inputs of CW and CCW,
set the SPI SEL switch to [OFF(2P)].
● When the motor is operated with the pulse signal and direction signal
input, set the SPI SEL switch to [ON(1P)].
● In the case that 1-pulse input method is selected, the CCW terminal becomes
direction signal input designating the direction of the motor rotation.
Drive pulse set to the CW terminal(CW+,CW-).
● The input timing is same with 2-pulse input method and 1-pulse input method .
As for input timing, refer to "10-3. (2)Drive pulse input(CW, CCW)"
SPI SEL
1P(ON)
2P(OFF)
Input type
1PULSE
2PULSE
CCW terminal(CCW+,CCW-)
direction set
Photo-coupler OFF: CCW direction
Photo-coupler ON : CW direction
-20-
Summary of Contents for GD-5510 -01
Page 13: ...GD 5510 01 Instructions Manual 3 2 AC Input Motor Output Terminal Block J2 J3 13 ...
Page 34: ...GD 5510 01 Instructions Manual 10 3 I O Signal 1 Example Circuit Connection 34 ...
Page 40: ...GD 5510 01 Instructions Manual 10 4 Dimensions Unit mm 40 ...
Page 43: ...GD 5510 01 Instructions Manual 43 ...
Page 44: ...GD 5510 01 Instructions Manual 44 ...
Page 45: ...GD 5510 01 Instructions Manual 45 ...
Page 46: ...GD 5510 01 Instructions Manual 46 ...