GDB-5K50
Instructions Manual
5.Installation
5-1.Conditions for Installation
Overheating may cause fire.
Mount it on a noncombustible member.
Keep it away from combustibles.
(1) Designed for incorporating into equipment used indoors, this product requires
to be installed in the following environment:
●Indoors (where it is not exposed to direct sun).
●Where ambient temperature and humidity are controlled within the range set
out in the specifications.
●Where there is no explosive, corrosive or inflammable gas.
●Where it can be protected from dust, salt or iron powder.
●Where the product main frame is not exposed to direct vibration or shock.
●Where it is not exposed to splashes of water, oil or chemicals.
(2) Install the driver at least 5mm away from other equipment.
However, please be installed to a distance of at least 15mm from the
heating element.
● Please contact us if you are not installed to a distance of at least 15mm
from the heating element.
(3) Take measures against accumulation of heat such as allowing generous space
around the driver or installing a fan so that heat release is taken care of.
(4) In the case that the overheat alarm signal is output, perform the cooling measure
of compulsion air cooling etc.
Use the driver on the condition that the overheat alarm signal is not output.
(5) Do not allow standing or placing anything heavy on the product.
heating
element
DRIVER
DRIVER
15mm or more
5mm or more
5mm or more
WARNING
5mm or more
5mm or more
-23-