Programming parameters
Once the melter and the control panel have been installed, the correct working
parameters must be programmed for the specific application to be performed.
Cantho melters/applicators simplify this task as much as possible, allowing
the operator to modify only those parameters that are necessarily variable for
each application.
Among the various parameters, it is necessary to program the set point
temperature values for each component connected and the value for
overheating warnings. There are two other parameters (weekly start-up and
shut-down programming and the standby temperature value) left to program
in advanced systems, although the factory default values are perfectly valid for
operational purposes.
Programming working temperatures
The general process for modifying set up temperature values for any
component is described below.
1. Select the component for which you wish to modify the value with the
up-down arrow.
The corresponding LED will blink quickly.
2. Using the up-down arrow under the display, select the desired value for
the set point temperature.
3. After ten seconds, the LED will stop blinking and the display will
change by default to the set point temperature, saving the changed
data.
This simple procedure should be repeated for each of the components whose
set point temperature value you wish to modify.
Selecting the overheating value
1. Press the buttons with the clock symbol and the down arrow under the
display at the same time to enter the special menu.
The choice of display units (ºC or ºF) will appear on the display.
2. Using the up arrow for element selection, we advance to the next
screen where the overheating symbol appears.
3. Select the desired value with the up-down arrow under the display.
160
160
024
024
160
160
160
160
ºC
ºC
10
10
_
_
_
_
_
_
Summary of Contents for Cantho
Page 1: ...ADHESIVE MELTER CANTHO INSTRUCTIONS MANUAL MA 5168 ENG 251019 GLUING SOLUTIONS ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS 4 14 MELTER OPERATION This page is intentionally left blank ...
Page 44: ...FOCKE MELER GLUING SOLUTIONS 5 6 MAINTENANCE This page is intentionally left blank ...
Page 49: ...ELECTRICAL DRAWINGS 7 1 MA 5168 ENG ADHESIVE MELTER CANTHO 7 ELECTRICAL DRAWINGS ...
Page 50: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 52: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWINGS This page is intentionally left blank ...
Page 62: ...FOCKE MELER GLUING SOLUTIONS 9 10 SPARE PART LIST This page is intentionally left blank ...
Page 64: ......