FOCKE MELER GLUING SOLUTIONS
6-2
TECHNICAL CHARACTERISTICS
Tank capacity
19.7 liters
37.4 liters
Pumping rate
29.3 kg/h 7cc/stroke pump (*)
66.0 kg/h 19cc/stroke pump (*)
66.0 kg/h 19cc/stroke pump (*)
Melting rate
19 kg/h (*)
30 kg/h (*)
Number of hydraulic outputs
6 (thread 9/16)
6 (thread 9/16)
Temperature range
(optional)
40 to 200 °C (104 to 392 °F)
40 to 230 °C (104 to 446 °F)
40 to 200 °C (104 to 392 °F)
40 to 230 °C (104 to 446 °F)
Temperature control
RTD ±0.5 °C (±1 °F)
Pt-100, Ni-120 or NTC-R
RTD ±0.5 °C (±1 °F)
Pt-100, Ni-120 or NTC-R
Max. working pressure (at 6 bar)
81.6 bar (1183 psi)
81.6 bar (1183 psi)
Max. installation power
(Maximum current allowed is 27A
per phase)
7400 W (2 electrical output)
11000 W (4 electrical output)
14600 W (6 electrical output)
8900 W (2 electrical output)
12500 W (4 electrical output)
16100 W (6 electrical output)
External functions
Inputs
Outputs
Unit On-Off • Standby On-Off •
Activity Control • Pumping On-Off •
Communications On-Off • Electrical
Outputs Inhibition
Standby • Zones Temperature OK •
Machine Ready • Running • Alarm •
Level • No Level
Unit On-Off • Standby On-Off •
Activity Control • Pumping On-Off •
Communications On-Off • Electrical
Outputs Inhibition
Standby • Zones Temperature OK •
Machine Ready • Running • Alarm •
Level • No Level
Electrical requirements
(optional)
(optional)
1N ~ 230V 50/60Hz + PE
3N ~ 400V 50/60Hz + PE
3 ~ 230V 50/60Hz + PE
3 ~ 400V 50Hz + PE with
transformer base
3N ~ 400V 50/60Hz + PE
3 ~ 230V 50/60Hz + PE
Ambient temperature
0 to 40 °C
0 to 40 °C
Dimension (LxWxH)
671 x 382 x 524 mm
671 x 382 x 875 mm (lid open)
738 x 435 x 673 mm
738 x 435 x 1067 mm (lid open)
Weight
60.2 kg (empty)
90.1 kg (empty)
(*)
Under standard conditions
Summary of Contents for Micron + 10
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Page 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Page 104: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...