MELER GLUING SOLUTIONS
6-4
MAINTENANCE
Replacing the module
Warning: Make sure that the applicator is hot before starting to extract
the module. In addition, bleed the pressure from the system and purge it to
remove any residual pressure that may remain inside the applicator. Likewise,
cut off the air supply to the applicator.
1- Remove the 2 screws with an Allen wrench (A). The side plates do not have
to be removed since these have holes prepared for the insertion of the Allen
wrench.
2- Slide the module downwards to remove it from the applicator (B), insert the
new module and place the 2 screws.
Warning: When removing the module, make sure that the seating gaskets
also come out and are not left inside.
Replacing the sensor and heating resistance
Warning: Before replacing the sensor or the heating resistance, disconnect
the electrical connections from the hose's applicator.
The side plates have to be removed before replacing any sensors or heating
resistances.