The management module does not start
1.
Check that the OpenSM has been started.
Power Cycle the Gateway:
To run the gateway through a power cycle
1.
Run:
(config) # reload halt
2.
Wait long enough to let the gateway halt, and verify there is no ping to it.
3.
Unplug the power cord.
4.
Plug in the power cord.
Gateway Fails to Boot:
1.
Reburn the firmware to the Flash memory, using the MFT tools.
The FabricIT-BXM last software update did not succeed:
1.
Connect the RS232 connector (CONSOLE) to a laptop.
2.
Push the reset button on the gateway or management module.
3.
You will have ~ 5 seconds to stop the U-Boot by pressing Control-B.
4.
Choose the image to upload. Only use image 1 or image 2.
U-Boot 2009.01-mlnx1.4 (May 12 2010 - 14:08:15)
CPU: AMCC PowerPC 460EX Rev. A at 1000 MHz (PLB=200, OPB=100, EBC=100
MHz)
Security/Kasumi support
Bootstrap Option H - Boot ROM Location I2C (Addr 0x52)
Internal PCI arbiter disabled
32 kB I-Cache 32 kB D-Cache
Board: Mellanox PPC460EX Board
FDEF: No
I2C: ready
DRAM: 2 GB (ECC enabled, 400 MHz, CL3)
FLASH: 16 MB
NAND: 1024 MiB
PCI: Bus Dev VenId DevId Class Int
PCIE0: link is not up.
PCIE1: successfully set as root-complex
01 00 15b3 bd34 0c06 00
Net: ppc_4xx_eth0, ppc_4xx_eth1
Hit Ctrl+B to stop autoboot: 0
Mellanox FabricIT
If the Gateway is powered off for any reason without using the proper shut
down procedure the Flash memory may be corrupted.
If the Flash memory is corrupted the Gateway may fail to boot. If this happens
talk to your Mellanox representative.