background image

Interfaces

Rev 1.0

24

Mellanox Technologies

14. WEEE Directive 

According to the WEEE Directive 2002/96/EC, all waste electrical and electronic 
equipment (EEE) should be collected separately and not disposed of with regular 
household waste.
Dispose of this product and all of its parts in a responsible and environmentally 
friendly way.

Summary of Contents for MUA9402E-2SF-100

Page 1: ...es www mellanox com Unified Fabric Manager SDN Appliance Hardware User Manual PN s MUA9402E 2SF 100 MUA9402E 2SF 1K MUA9402E 2SF 250 MUA9402E 2SF 2K MUA9402E 2SF 4K MUA9402E 2SF 500 MUA9402E 2SF HA Mo...

Page 2: ...ost updated list of Mellanox trademarks visit http www mellanox com page trademarks NOTE THIS HARDWARE SOFTWARE OR TEST SUITE PRODUCT PRODUCT S AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX T...

Page 3: ...nt Ports eth0 eth1 19 3 4 ConnectX 4 QSFP Ports 20 3 4 1 QSFP Port Interfaces 20 3 5 RJ 45 Ethernet Connector for Remote Management 20 3 6 USB Interface 21 3 7 System Cold Reset 21 3 8 UFM SDN Applian...

Page 4: ...Troubleshooting 36 Appendix A UFM SDN Appliance Specifications 38 A 1 Approved Cables 40 A 2 EMC Certifications 40 A 3 China CCC Warning Statement 40 Appendix B Field Replaceable Units 41 Appendix C A...

Page 5: ...e 6 PS Unit Status LED Configurations 15 Table 7 NIC Activity Indications 18 Table 8 Physical and Logical Link Indication 20 Table 9 Serial Terminal Program Configuration 33 Table 10 Mellanox UFM SDN...

Page 6: ...16 Figure 10 Cold Reset Button 17 Figure 11 NIC Activity LEDs 17 Figure 12 Front Side Interfaces 18 Figure 13 Rear Side Interfaces 19 Figure 14 Illustration of InfiniBand Port Connector Interfaces 20...

Page 7: ...Rev 1 0 7 Mellanox Technologies Document Revision History Table 1 Revision History Table Revision Date Description 1 0 April 2017 Initial release...

Page 8: ...lanox All of these documents can be found on the Mellanox Website They are available either through the product pages or through the support page with a login and password Table 2 Reference Documents...

Page 9: ...ocument to indicate information that is important to the user Abbreviations This icon makes recommendations to the user This icon indicates information that is helpful to the user This icon indicates...

Page 10: ...d software which bridges the gap between servers applications and fabric elements Thus it enables administrators to manage and optimize clusters of various sizes UFM SDN Appliance is offered as a pre...

Page 11: ...Overview Rev 1 0 11 Mellanox Technologies Figure 2 Pull Out Tab Example...

Page 12: ...hows the front and rear sides of the appliance The system supports the following 4 RJ 45 connectors 5 USB connectors Status LEDs 2 Hot swap power modules 2 Hot swap hard disk drive HDD drawers Figure...

Page 13: ...Activity LED C NIC 2 Activity LED D System Cold Reset Button E System Status LED F Power Button w Integrated LED G Hard Drive Activity LED Table 5 PS Unit Status LED Configurations LED Color Status Of...

Page 14: ...Off Button and Indicators The primary power supply unit PS1 is located on the left side of the rear side panel with PS2 on the right of the PS1 Amber Fatal Error occurred non recoverable condition sy...

Page 15: ...hing the button or by using the remote management Table 6 PS Unit Status LED Configurations LED Color Status Solid Green OK the Power supply is delivering the correct voltage Off Off no power to any o...

Page 16: ...tivity Solid Amber A hard drive failure has occurred Flashing Amber RedundantArray of Independent Disks RAID is being rebuilt This hap pens after replacing a faulty drive Activity LED Off The system i...

Page 17: ...ers 2 1 2 Reset Button Figure 10 Cold Reset Button The appliance has a system cold reset button Pressing this button performs a forced reset of the appliance hardware For a graceful shutdown of the sy...

Page 18: ...s 1 on off button with an integral LED 1 RJ 45 serial port 2 X 100M 1Gb Ethernet connectors 2 EDR ports 1 remote management port 5 USB ports System Cold reset button Figure 12 Front Side Interfaces Ta...

Page 19: ...anagement Ports eth0 eth1 These 2 RJ 45 ports are found on the rear side of the appliance see Figure 13 The eth0 eth1 and remote management interfaces are pre configured as DHCP and the initial host n...

Page 20: ...necting to a remote management controller It usu ally connects to the same management network as eth0 For using out of the box DHCP set tings Default hostname for the appliance over eth0 is ufm applia...

Page 21: ...ces closing all files flushing all caches etc use the CLI 3 8 UFM SDN Appliance Installation and Operation Installation and initialization of the UFM SDN Appliance are straightforward processes requir...

Page 22: ...inches of clearance around the ventilation openings The chassis should not be stacked on any other equipment If the chassis falls it can cause bodily injury and equipment damage This product includes...

Page 23: ...s There is a risk of explosion should the battery be replaced with a battery of an incorrect type Dispose of used batteries according to the instructions For North American power connection select a p...

Page 24: ...ording to the WEEE Directive 2002 96 EC all waste electrical and electronic equipment EEE should be collected separately and not disposed of with regular household waste Dispose of this product and al...

Page 25: ...may have occurred during shipping The appliance comes packed with the following items 1 X appliance 2 X installation rails one right hand and one left hand 2 X power cables one for each PS unit Type...

Page 26: ...ide View 3 Slide the appliance into the rails as shown in the diagrams in the installation guide packed in the box Figure 18 Inserting Appliance Into Rails 4 Ground the appliance see Grounding the App...

Page 27: ...to the same switch but Mellanox recom mends connecting to two separate switches to ensure SM connectivity to the fabric Figure 20 Connecting Up the UFM SDN Appliance 4 3 Grounding the Appliance Check...

Page 28: ...is on Do not hot swap the power supply if your appliance has only one power supply You must power down the system to replace the power supply unit there is only one PS unit in the appliance The power...

Page 29: ...If a power supply is installed grab the handle with your thumb pointing toward the latch Push the latch with your thumb towards the handle while you pull the power supply out of the appliance Figure...

Page 30: ...takes up to 48 hours but does not interrupt with appliance operation 1 Power down the appliance before removing the HDD 2 Remove the HDD by pressing the latch button and opening the lever 3 Slide the...

Page 31: ...ives or to disas semble for environmentally approved disposal 4 8 Supported Approved Cables For a list of approved cables for this appliance see http www mellanox com related docs user_manuals Mellano...

Page 32: ...ttery This procedure is only to be used when you will be disassembling this appliance before discard ing to comply with regulations regarding disposal of batteries Remove the cover Remove the battery...

Page 33: ...supports a direct connection via a serial port Please follow the steps below to con nect to the appliance 1 Connect the host PC to the RJ 45 port of the appliance system using the supplied cable The C...

Page 34: ...n eth0 interface yes Hostname Perform this step to obtain an IP address for the appli ance eth0 is the management port of the appliance If you wish the DHCP server to assign the IP address type yes an...

Page 35: ...ion Example Mellanox configuration wizard Do you want to use the wizard for initial configuration y Step 1 Hostname server name Step 2 Use DHCP on eth0 interface no Step 3 Use zeroconf on eth0 interfa...

Page 36: ...ecommended to clean the fan unit and remove the dust from the front and rear panels of the appliance using a vacuum cleaner 4 The link LED for the Ethernet connector does not come on 1 Check that both...

Page 37: ...e 3 Wait 5 minutes 4 Plug in the appliance and press the Power Button w Integrated LED 5 If the appliance does not come on check the power supplies 6 If the appliance comes on use the UFM management s...

Page 38: ...pation 750 Watt Max 2560 BTU hour Power and Environmental Input Voltage CPU Input Voltage 750W power supply module 100 127 V at 50 60 Hz 8 2 A 200 240 V at 50 60 Hz 4 4 A CPU 2 Intel Xeon E5 2620 v4 C...

Page 39: ...25 40 50 100 Gb s Regulatory Compliance Safety EMC Emissions Safety US Canada cTUVus EU CE International CB Russia GOST R Argentina S mark DoC EMC Emissions USA FCC Class A Canada ICES 003 Class A EU...

Page 40: ...nox_approved_cables pdf A 2 EMC Certifications The list of approved certifications per switch in different regions of the world is located on the Mellanox Website at http www mellanox com related docs...

Page 41: ...Number Description Power Supply 00WT199 Power Supply w PSU Side to Connector side airflow for Mellanox UFM Appli ance 1U VPI Server HDD 00WT141 Hard Drive for Mellanox UFM SDN Appliance 1U VPI Server...

Page 42: ...ce libre autour des ouver tures de ventilation Le ch ssis ne doit pas tre empil sur un autre mat riel Si le ch ssis tombe il peut pro voquer des blessures corporelles et des d gradations de biens Ce p...

Page 43: ...re des forts courants de fuite est essentielle avant le branchement de l alimentation Avant de brancher l appareil la conduite d alimentation les vis de protection la terre du terminal de l appareil d...

Page 44: ...tion contre la surintensit Un appareil de protection r pertori facilement accessible contre la surintensit du circuit de branchement et calibr 20A doit tre incorpor dans le c blage lectrique du b time...

Page 45: ...ent tre limin s avec les d chets m nagers Veuillez disposer de ce produit et de tous ses composants de mani re responsable et respectueuse de l environnement Caution Slide rail mounted equipment is no...

Page 46: ...s ffnungen sein um einen einwandfreien Luftstrom zu gew hrleisten Das Chassis sollte nicht auf andere Ger te gestapelt werden Wenn das Chassis herunt erf llt kann es zu Verletzungen und Besch digungen...

Page 47: ...m und qualifiziertem Personal installiert aus getauscht oder gewartet werden Die Entsorgung dieses Ger ts sollte unter Beachtung aller nationalen Gesetze Bestim mungen erfolgen Dieses Ger t sollte unt...

Page 48: ...l Electrical Code F r Nordamerika m ssen in bereinstimmung mit den gel tenden Vorschriften in der US amerikanischen National Electrical Code und dem Canadian Electrical Code Kabel f r den Anschluss an...

Page 49: ...uipo es muy pesado se debe mover nicamente mediante un elevador mec nico para evitar lesiones Esta unidad ha sido ideada para instalar en lugares de acceso restringido No se debe utilizar el equipo en...

Page 50: ...son flexibles su conexi n a los conec tores y su desconexi n se deben efectuar con mucho cuidado Para ver advertencias o instrucciones especiales consultar al fabricante del cable Al instalar o realiz...

Page 51: ...io deber prover un medio para la conexi n con la puesta a tierra de protecci n y un t cnico de servicio deber conectar permanentemente el equipo a dicho medio de conexi n Un T CNICO DE SERVICIO compro...

Page 52: ...or separado y no se deben eliminar junto con residuos dom sticos Al deshacerse de este producto y de todas sus partes h galo de una manera respons able y respetuosa con el medio ambiente Caution Slide...

Page 53: ...be plugged into a wall socket outlet which is connected to protective earth Socket outlets which are not con nected to earth shall not be used Finland Norway Sweden Do not connect this unit to any ou...