2.7.1.1 Disable Dynamic Host Configuration Protocol (DHCP)
DHCP is used for automatic retrieval of management IP addresses.
2.7.1.2 Manual Host Configuration
To perform initial configuration of the system:
Step 1.
Connect a host PC to the Console RJ45 (
) port of the system, using the supplied harness
cable (DB9 to RJ45). Make sure to connect to the Console RJ45 port and not to the (Ethernet)
MGT port.
Step 2.
Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera Term) on
your host PC with the settings described in
. Once you perform that, you should get the
CLI prompt of the system.
Step 3.
Login as
admin
and use
admin
as password. On the first login, the MLNX-OS configuration
wizard will start.
Step 4.
To configure network attributes and other initial parameters to the system, follow the configu-
ration wizard as shown in
If a user connects through SSH, runs the wizard and turns off DHCP, the connection is
immediately terminated, as the management interface loses its IP address.
<localhost># ssh admin@<ip-address>
Mellanox MLNX-OS Switch Management
Password:
Mellanox Switch
Mellanox configuration wizard
Do you want to use the wizard for initial configuration?
yes
Step 1: Hostname? [my-switch]
Step 2: Use DHCP on mgmt0 interface? [yes] no
<localhost>#
In such case the serial connection should be used.
Table 10 - Serial Terminal Program Configuration
Parameter
Setting
Baud Rate
115200
Data bits
8
Stop bits
1
Parity
None
Flow Control
None
Summary of Contents for Spectrum SN2410
Page 72: ...Mellanox Technologies 72 8 9 10 11 12 13...
Page 73: ...Rev 1 2 Mellanox Technologies 73 14 15 16 17 18 19...
Page 75: ...Rev 1 2 Mellanox Technologies 75 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 76: ...Mellanox Technologies 76 10 11 12 13 14 15 16 UL 4mA...
Page 78: ...Mellanox Technologies 78 23 24 China CCC Warning Statement TN IT...
Page 91: ...Rev 1 2 Mellanox Technologies 91 7 8 9 10 11 12 13...