Installation
Rev 1.2
Mellanox Technologies
22
Figure 11: Attaching the Brackets to the Rack
Step 6.
Slide the two blades into the left and right rails, and adjust them to fit your rack's depth. Use
four M6 screws (D) to fix the blades into the rack. Do not tighten the screws yet.
Figure 12: Sliding the Blades in the Rails
Step 7.
Secure the system in the rack by tightening the 8 screws inserted in Step 5 and Step 6 with a
torque of 4.5±0.5 Nm.
2.4.1.1 Removing the System from the Rack
To remove a unit from the rack:
Step 1.
Turn off the system and disconnect it from peripherals and from the electrical outlet.
While your installation partner is supporting the system’s weight:
Step 2.
Loosen the screws attaching the brackets to the rack. Do not remove them yet.
Step 3.
Loosen the screws attaching the blades to the rack, and pull the blades towards you, while your
partner is holding the system.
Step 4.
Extract the loosened screws from Step 2 and dismount the system from the rack.
Step 5.
Remove the rails and brackets from the chassis by unscrewing 8 screws.