Installation
Rev 1.2
Mellanox Technologies
29
• 4x Phillips100 DEG F.H TYPE-I ST.ST 6-32 X 1/4 screw with around patch (D).
¹ Other threads are available by special order: M5, 10-32, 12-24
² G-type cage-nut is available by special order.
Figure 22: Rack Rail Kit Parts
Before mounting the system to the rack, select the way you wish to place the system. Pay atten-
tion to the airflow within the rack cooling, connector and cabling options.
While planning how to place the system, consider the two installation options shown in
, and review the following points:
• Make sure the system air flow is compatible with your installation selection. It is
important to keep the airflow within the rack in the same direction.
• Note that the part of the system to which you choose to attach the rails (the front panel
direction, as demonstrated in Option 1 or the FRUs direction, as demonstrated in Option
2) will determine the system’s adjustable side. The system’s part to which the blades are
attached, will be adjacent to the cabinet.
• In case there are cables that cannot bend within the rack, or in case more space is
needed for cable bending radius, it is possible to recess the connector side or the FRU
side by 3.5" (8.9 cm), by optional placement of the system’s rails.
• The FRU side is extractable. Mounting the rack blades inverted to the FRU side (Option
2) will allow you to slide the FRUs, in and out.
Summary of Contents for Spectrum SN2410
Page 72: ...Mellanox Technologies 72 8 9 10 11 12 13...
Page 73: ...Rev 1 2 Mellanox Technologies 73 14 15 16 17 18 19...
Page 75: ...Rev 1 2 Mellanox Technologies 75 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 76: ...Mellanox Technologies 76 10 11 12 13 14 15 16 UL 4mA...
Page 78: ...Mellanox Technologies 78 23 24 China CCC Warning Statement TN IT...
Page 91: ...Rev 1 2 Mellanox Technologies 91 7 8 9 10 11 12 13...