2.5.1.2 Using Breakout Cables with Cumulus Linux
If you are using 4x10G direct attach copper cables or active optical cables, edit the
/etc/cumu
-
lus/ports.conf
to enable support for these cables, then restart the switchd service using the
sudo systemctl restart switchd
command. For more details, see
Figure 29: Breakout or Fanout Cables
2.5.1.3 SN2700 Splitting Options
Figure 30: SN2700 Splitting Options
The top QSFP ports marked in green are splittable to 4 SFP ports, each. The bottom QSFP ports
(gray) are blocked when the upper ports are in split mode. All QSFP ports marked in yellow can
be split to 2 SFP ports.