Installation
Rev 1.2
Mellanox Technologies
41
Figure 34: PS Unit Pulled Out
To insert a power supply unit:
Step 1.
Make sure the mating connector of the new unit is free of any dirt and/or obstacles.
Step 2.
Insert the power supply unit by sliding it into the opening, until a slight resistance is felt.
Step 3.
Continue pressing the power supply unit until it seats completely. The latch will snap into
place, confirming the proper installation.
Step 4.
Insert the power cord into the supply connector.
Step 5.
Insert the other end of the power cord into an outlet of the correct voltage.
2.8.2
Fans
The system can fully operate if one fan FRU is dysfunctional or missing. Failure of more than
one fan is not supported.
Do not attempt to insert a power supply unit with a power cord connected to it.
The green power supply unit indicator should light. If it does not, repeat the whole pro-
cedure to extract the power supply unit and re-insert it.
Make sure that the fans have the air flow that matches the model number. An air flow
opposite to the system design will cause the system to operate at a higher (less than
optimal) temperature.