Interfaces
Rev 1.2
Mellanox Technologies
48
Table 16 - Fan Status Rear LED Assignments (One LED per Fan)
4.2.1.3 Power Supply Status LEDs
Figure 39: Power Status LED
There are two power supply inlets in the system (for redundancy). The system can operate with
only one power supply connected. In case the power supply is an FRU, a second power supply
unit can be added to support hot-swap ability. Each power supply unit has a single 2 color LED
on the right side of the unit, that indicates the status of the unit.
Table 15 - Fan Status Front LED Assignments
LED
Behavior
Description
Action Required
Solid Green All fans are up and running.
N/A
Solid Red
Error, one or more fans are not operating prop-
erly.
The faulty FRUs should be replaced.
Off
System boot
N/A
LED
Behavior
Description
Action Required
Solid Green A specific fan unit is operating.
N/A
Solid Red
A specific fan unit is missing or not
operating properly.
The fan unit should be replaced.
Off
System boot
N/A
Risk of Electric Shock!
With the fan module removed, power pins are accessible within the module cavity.
Do not insert tools or body parts into the fan module cavity.