Code Parameter
Min. Max. Incre-
ment
De-
fault
Unit
Comment
43
Air flow for supply
air in supply air
operation ventila-
tion program
0
100
1
50
m
3
/h
InControl pushbutton sensor
and M-WRG-FBH wireless
remote control
46
Air flow for extract
air in extract air
operation ventila-
tion program
0
100
1
50
m
3
/h
InControl pushbutton sensor
and M-WRG-FBH wireless
remote control
47
Air flow for supply
air in extract air
operation ventila-
tion program
0
100
1
0
m
3
/h
InControl pushbutton sensor
and M-WRG-FBH wireless
remote control
196
Cross-ventilation
running time
0
1440 1
120
min
57
Ventilation level
for continuous
operation
0
100
1
30
m
3
/h
Ventilation levels for supply
air and extract air are set at
the same time
50
(3)
InControl push-
button sensor:
CO
2
control or
automatic mode
0
1
1
0
-
0: CO
2
control
1: automatic mode
101
(4)
External switch
mode
0
2
1
1
0 = deactivated
1 = air flow
2 = mode
3 = not used
131
Summer/winter
changeover
0
1
1
1
0 = winter
1 = summer
123
Time zone
-720 840
1
60
min
Setting in minutes –/+ from
UTC, +60 = Germany
96
(5)
InControl push-
button sensor
standby ON/OFF
0
1
1
1
0 = standby OFF
1 = standby ON
133
(1)
Smoke detector
input mode
0
18
1
18
Unit OFF
134
Smoke detector
contact type
0
1
1
0
0 = NO contact
1 = NC contact
151
CO
2
control with
2 sensors
0
1
1
0
0 = Off
1 = On
152
(6)
Threshold for
VOC control
0
4000 1
1500
ppm
Threshold for VOC control
above which the ventilation
unit increases the ventilation
level
153
(6)
Min. air flow for
supply air with
2 sensors
0
100
1
10
m
3
/h