13
OPERATION INSTRUCTIONS
Lighting Instructions
Note:
Note:
Visually check the burner flame against the illustrations below:
Flame should be blue with slight yellow tips.
You should see a smaller flame in LOW position than seen on HIGH. Perform flame check
prior to each use. If only low flame is seen, refer to “Burner flame is low” in the
“TROUBLESHOOTING” on page 16.
1. Ensure that the LP gas tank valve is OFF.
2. Push the control knob in, turn to
OFF
, and wait 5
minutes for any gas to clear.
3. Turn the LP tank valve ON.
4. Push control knob in and slowly rotate to
HIGH
. This will
activate the built-in igniter and light the burner. Once
burner is lit, hold control knob in for 30 seconds and
then release. If the burner fails to remain lit or becomes
extinguished, repeat step 4 before attempting to relight.
5. Turn the control knob from
HIGH
to
LOW
to the desired
heat setting.
For complete shutdown
1. Please turn the knob to
HIGH
first, then push and turn
to
OFF
for complete shut off.
2. Turn the LP gas tank valve OFF before removing the
LP gas tank. If you experience any ignition problem,
turn off the heater and gas supply, and consult
“Troubleshooting” on page 16.
HIGH
LOW
OFF