background image

 16

TROUBLESHOOTING                                                                                               

             

Problem Possible 

Cause 

Corrective 

Action 

Burner won’t light  Gas pressure is low. 

 
The orifice is blocked. 
Control knob is not in “High” 
position. 

Turn tank valve “OFF” and replace 
the tank 
Clear blockage. 
Turn control knob to “High” 

Burner flame is 

low 

Gas pressure is low. 
 
The control knob is not positioned 
at “High”. 

 

The burner jet may be partially 
blocked. 
 
Outdoor temperature is less than 
40°F and tank is less than 1/4 full. 
 
Supply hose is bent or kinked. 

Turn tank valve “OFF” and replace 
the tank. 
Position the control knob at “High” 
 
 
Clear blockage. 
 
 
Use a full tank. 
 
 
Straighten the hose. 

Carbon build-up 

Build-up of carbon can accumulate 
over time. 

Wipe off before lighting. 

Thick black 

smoke 

Blockage 

in 

burner 

Remove blockage and clean 
burner inside and outside. 

 

 

 

 

1-YEAR LIMITED WARRANTY                                                                                               

The appliance has been manufactured under the highest standards of quality and 
workmanship. We warrant to the original consumer / purchaser that all aspects of this 
product will be free of defects in material and workmanship for one (1) year from the date of 
purchase. A replacement for any defective part will be supplied free of charge for installation 
by the consumer. Defects or damage caused by the use of other than genuine parts are not 
covered by this warranty .This warranty shall be effective from the date of purchase as 
shown in the purchaser’s receipt. This warranty is valid for the original consumer purchaser 
only and excludes industrial, commercial or business use of the product, product damage 
due to shipment or failure which results from alteration, product abuse, or product misuse, 
where performed by a container, service company, or consumer. We will not be responsible 
for labor charges and/or damage incurred in installation, repair or replacement, nor for 
incidental or consequential damage. This warranty gives you specific legal rights, and you 
may also have the other rights that vary from state to state. 

If problems cannot be corrected by using these methods, pleas contact 
1-855-CHANT-US (1-855-242-6887) for assistance. 

Summary of Contents for PG195H

Page 1: ...structions thoroughly before installing or servicing this equipment WARNING For outdoor use only IMPORTANT DO NOT RETURN Question problems missing parts Don t return the product to stores please call...

Page 2: ...ICATIONS Product Specifications Certification CSA Height Overall 86 60 inches Reflector Diameter 31 50 inches Rated Heat Input 45 000 BTU HR Fuel Propane LP Gas Supply 20 Lb LP Gas cylinder Manifold P...

Page 3: ...e a ground screw to fix the base of the heater on the surface where the heater is installed Fix the base on an incline no wider than 15 degrees 5 Place the propane hose with regulator assembly out of...

Page 4: ...t the cylinder when the appliance is not in use 18 Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance 19 Store the cylinder outdoors in...

Page 5: ...roductive harm b Handling the brass material on this product exposes you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands aft...

Page 6: ...RIPTION QUANTITY PART DESCRIPTION QUANTITY A Top Dome 1 F Lower Pole 1 B KD Dome 4 G Cylinder Housing Assembly 1 C Burner Assembly 1 I Base 1 D Upper Pole 1 J Wheel Assembly 1 E Beauty Ring 1 K Regula...

Page 7: ...ompare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble the product Contact customer service for replacement parts Estimated Assembly Tim...

Page 8: ...linder Housing assembly G using M5 x 8 mm black bolts DD through the Shroud Fix Brackets Note The doors on the Cylinder Housing Assembly G should be on the opposite side of the Wheel Assembly J J I G...

Page 9: ...urner Assembly C 6 Feed the Regulator Hose Assembly K and connect the Burner Assembly C to the Upper Pole D 6 1 Feed the Regulator Hose Assembly K into and go through the Upper Pole D 6 2 Screw Burner...

Page 10: ...rew Upper Pole D onto Lower Pole F until the holes on Upper Pole D is aligned to the holes on top of Lower Pole F Fix them by using four M5 x 8 mm Black Bolts DD Ensure they are fully tightened 8 Atta...

Page 11: ...TO MAKE THIS CONNECTION Be careful not to cross threads when screwing in fitting To disconnect the LP Gas cylinder first make sure the cylinder valve is OFF Then turn the knob on the regulator counte...

Page 12: ...le of the solution onto the gas hose regulator and regulator cylinder and hose connection c Turn on gas cylinder valve Inspect the connections and look for bubbles d If no bubbles appear the connectio...

Page 13: ...r 3 Turn the LP tank valve ON 4 Push control knob in and slowly rotate to HIGH This will activate the built in igniter and light the burner Once burner is lit hold control knob in for 30 seconds and t...

Page 14: ...excessively uneven d Burner makes popping noises during use Note A slight pop is normal when burner is extinguished Carbon deposits may create a fire hazard Keep dome and emitter clean at all times Do...

Page 15: ...irculating air passageways clean Signs of possible blockage include Gas odor with extreme yellow tipping of flame Heater does NOT reach the desired temperature Heater glow is excessively uneven Heater...

Page 16: ...nsumer purchaser that all aspects of this product will be free of defects in material and workmanship for one 1 year from the date of purchase A replacement for any defective part will be supplied fre...

Page 17: ...sembly 195H001 C1 Burner Chamber Assembly 5206424 C2 insulation plate 195H002 C3 Thermocouple 2409043 C4 Ignition Pin 195H003 C5 Tilt Switch 2310662 C6 Knob 2100462 D Upper Pole 195H004 E Beauty Ring...