background image

Product List:

  

MEMC-P270AMA, MEMC-P275AMA, MEMC-P280AMA, MEMC-P285AMA, MEMC-P290AMA 
MEMC-P270ACA, MEMC-P275ACA, MEMC-P280ACA, MEMC-P285ACA, MEMC-P290ACA 
MEMC-P280AMC, MEMC-P285AMC, MEMC-P290AMC, MEMC-P295AMC, MEMC-P300AMC, MEMC-P305AMC 
MEMC-P280ACC, MEMC-P285ACC, MEMC-P290ACC, MEMC-P295ACC, MEMC-P300ACC, MEMC-P305ACC

Installation Manual

  

for MEMC Silvantis

TM

 72 cell Photovoltaic Modules

Summary of Contents for MEMC-P270ACA

Page 1: ...270ACA MEMC P275ACA MEMC P280ACA MEMC P285ACA MEMC P290ACA MEMC P280AMC MEMC P285AMC MEMC P290AMC MEMC P295AMC MEMC P300AMC MEMC P305AMC MEMC P280ACC MEMC P285ACC MEMC P290ACC MEMC P295ACC MEMC P300AC...

Page 2: ...nstallation 7 5 1 Planning and Design 7 5 2 Module Wiring 7 5 3 Grounding 8 5 4 Electrical Installation Warnings 8 6 0 Disclaimer of Liability 9 7 0 Mechanical and Electrical Parameters and Specificat...

Page 3: ...te and EVA back sheet substrate These laminates are secured inside an aluminum frame to provide rigidity and a means for attachment to mounting sub structures The frames should not be modified or remo...

Page 4: ...mmissioning trouble shooting disconnecting or connecting a PV system Trouble shooting should include planning checking disconnecting cause seeking replacement and record keeping Do not install or hand...

Page 5: ...ations For mounting locations for clamps or bolt for specified load please refer to Table on page 5 Each module should be mounted using four bolts through the mounting holes on the rear side of the mo...

Page 6: ...modules are rated for a maximum rear load of 2400 Pa and a maximum front load of 5400 Pa when fixed to the mounting holes on the long side frames only Structural rails running parallel to the length...

Page 7: ...nstallers should adhere to all applicable local regional and national codes and regulations when designing and constructing the photovoltaic system Do not stand or walk on any surface of the modules D...

Page 8: ...tional codes and regulations when designing and constructing the photovoltaic system Note In colder climates it may be necessary to further reduce the maximum number of modules in series by using Vocm...

Page 9: ...regional and national codes and regulations when designing and constructing the photovoltaic system Photovoltaic modules produce DC electrical energy from light When illuminated each module can have a...

Page 10: ...arranty shall be VOID if handling and installation of the product does not conform to MEMC s written installation instructions or if the product has been reworked repaired or otherwise modified in a m...

Page 11: ...12 MEMC P285AMA 285 44 5 8 71 14 6 35 1 8 18 MEMC P285ACA 285 44 5 8 71 14 6 35 1 8 18 MEMC P290ACA 290 44 7 8 78 14 8 35 4 8 20 MEMC P290AMA 290 44 7 8 78 14 8 35 4 8 20 Copyright 2012 MEMC Electroni...

Page 12: ...976 77 8 C 50 2 0 D 40 1 6 E 940 37 0 F 1 926 75 8 G 1 188 46 8 H 594 23 4 L 1 000 39 4 Module Dimensions Mounting Hole Spacing Dimension MM INCH Dimension MM INCH Cable Length for ACA and ACC Cable L...

Page 13: ...Bolt Stack Details Center Mount Option 8 0 Appendix 8 2 Module illustrations Installation Manual MEMC Silvantis 72 cell PV modules Copyright 2012 MEMC Electronic Material 12 of 13...

Page 14: ...00 V UL 1000 V IEC Temperature rating 40 C to 90 C 40 C to 85 C Qualification TUV 2PFG UL PV wire EN 50521 UL for PV sys Copyright 2012 MEMC Electronic Material Controlled Document MEMC Electronic Mat...

Reviews: