1.0 InTroduCTIon 

The purpose of this guide is to provide general information regarding the proper installation and handling of MEMC photovoltaic 
modules that serve residential, commercial, and industrial segments. System design, construction, and commissioning should be 
performed by qualified personnel only. 

To ensure system integrity, designers, installers and operators must meet all mechanical and electrical requirements for the system 
and its components. It is the responsibility of the system designer and installer to ensure that all codes and requirements are followed 
as well. 

Please review all the sections that pertain to proper installation of modules listed in this Guide. The instructions detailed in this guide 
must be followed throughout the module’s lifetime deployment. If you need additional information about the safe, proper use and 
handling of MEMC photovoltaic module products, please contact MEMC. 

2.0 PhoTovolTaIC Modules ProduCT Code

This guide is to be used for MEMC Silvantis

TM

 72 cell photovoltaic (PV) module installation. Please refer to the following module 

numbers before using the guide: P270AMA, P275AMA, P280AMA, P285AMA, P290AMA, P270ACA, P275ACA, P280ACA, 
P285ACA, P290ACA 

Modules with anti-reflective coating (AR coating or ARC): P280ACC, P285ACC, P290ACC, P295ACC, P300ACC, P305ACC, 
P280AMC, P285AMC, P290AMC, P295AMC, P300AMC, P305AMC

3.0 Module overvIew 

MEMC Silvantis Photovoltaic modules consist of a series of electrically interconnected crystalline silicon solar cells that are sealed 
within a laminated sheet of tempered glass superstrate* and EVA/back-sheet substrate. These laminates are secured inside an 
aluminum frame to provide rigidity and a means for attachment to mounting sub-structures. The frames should not be modified or 
removed. 

* Tempered glass may have AR coating.

• 

Photovoltaic modules are designed and constructed for outdoor use. Do not submerge modules in water at any time.

• 

The front and back of each module is labeled with a product bar code. Do not cover, remove or deface these labels. This may 
be required for product identification. 

• 

Damage to the glass surface or the anti-reflective coating can impact the power output and overall efficiency of the system. 
Scratches, handling marks, or any damage to the glass surface must be avoided. 

• 

For best performance and to avoid potential issues, keep the front side of the module clean and free of obstructions including 
covers, tape, adhesives, paint and debris.

3.1 sTorage, unPaCkIng, and handlIng

• 

Packaged modules must be stored in a dry and ventilated area.    

• 

Packaged modules must not be exposed to rain, snow, hail or other environmental conditions that may compromise the 
packaging material and the modules.  

• 

Packaged modules must be on appropriate provided pallets and must not be stacked more than two pallet high for storage. 

• 

Once the modules are opened, store modules in a dry and ventilated room.

• 

Modules should never be stored in a wet environment.

• 

Upon unpacking, do not carry a module by its wires or junction box. Only carry a module by its frame with two or more 
people. 

• 

Precaution should be taken to avoid damage to the glass surface with or without anti-reflective coating due to improper 
handling during storage or unpacking.

Installation Manual: MeMC silvantis 72 cell Pv modules

© Copyright 2012 MEMC Electronic Material

2 of 13

Summary of Contents for MEMC-P270ACA

Page 1: ...270ACA MEMC P275ACA MEMC P280ACA MEMC P285ACA MEMC P290ACA MEMC P280AMC MEMC P285AMC MEMC P290AMC MEMC P295AMC MEMC P300AMC MEMC P305AMC MEMC P280ACC MEMC P285ACC MEMC P290ACC MEMC P295ACC MEMC P300AC...

Page 2: ...nstallation 7 5 1 Planning and Design 7 5 2 Module Wiring 7 5 3 Grounding 8 5 4 Electrical Installation Warnings 8 6 0 Disclaimer of Liability 9 7 0 Mechanical and Electrical Parameters and Specificat...

Page 3: ...te and EVA back sheet substrate These laminates are secured inside an aluminum frame to provide rigidity and a means for attachment to mounting sub structures The frames should not be modified or remo...

Page 4: ...mmissioning trouble shooting disconnecting or connecting a PV system Trouble shooting should include planning checking disconnecting cause seeking replacement and record keeping Do not install or hand...

Page 5: ...ations For mounting locations for clamps or bolt for specified load please refer to Table on page 5 Each module should be mounted using four bolts through the mounting holes on the rear side of the mo...

Page 6: ...modules are rated for a maximum rear load of 2400 Pa and a maximum front load of 5400 Pa when fixed to the mounting holes on the long side frames only Structural rails running parallel to the length...

Page 7: ...nstallers should adhere to all applicable local regional and national codes and regulations when designing and constructing the photovoltaic system Do not stand or walk on any surface of the modules D...

Page 8: ...tional codes and regulations when designing and constructing the photovoltaic system Note In colder climates it may be necessary to further reduce the maximum number of modules in series by using Vocm...

Page 9: ...regional and national codes and regulations when designing and constructing the photovoltaic system Photovoltaic modules produce DC electrical energy from light When illuminated each module can have a...

Page 10: ...arranty shall be VOID if handling and installation of the product does not conform to MEMC s written installation instructions or if the product has been reworked repaired or otherwise modified in a m...

Page 11: ...12 MEMC P285AMA 285 44 5 8 71 14 6 35 1 8 18 MEMC P285ACA 285 44 5 8 71 14 6 35 1 8 18 MEMC P290ACA 290 44 7 8 78 14 8 35 4 8 20 MEMC P290AMA 290 44 7 8 78 14 8 35 4 8 20 Copyright 2012 MEMC Electroni...

Page 12: ...976 77 8 C 50 2 0 D 40 1 6 E 940 37 0 F 1 926 75 8 G 1 188 46 8 H 594 23 4 L 1 000 39 4 Module Dimensions Mounting Hole Spacing Dimension MM INCH Dimension MM INCH Cable Length for ACA and ACC Cable L...

Page 13: ...Bolt Stack Details Center Mount Option 8 0 Appendix 8 2 Module illustrations Installation Manual MEMC Silvantis 72 cell PV modules Copyright 2012 MEMC Electronic Material 12 of 13...

Page 14: ...00 V UL 1000 V IEC Temperature rating 40 C to 90 C 40 C to 85 C Qualification TUV 2PFG UL PV wire EN 50521 UL for PV sys Copyright 2012 MEMC Electronic Material Controlled Document MEMC Electronic Mat...

Reviews: