1.0 InTroduCTIon
The purpose of this guide is to provide general information regarding the proper installation and handling of MEMC photovoltaic
modules that serve residential, commercial, and industrial segments. System design, construction, and commissioning should be
performed by qualified personnel only.
To ensure system integrity, designers, installers and operators must meet all mechanical and electrical requirements for the system
and its components. It is the responsibility of the system designer and installer to ensure that all codes and requirements are followed
as well.
Please review all the sections that pertain to proper installation of modules listed in this Guide. The instructions detailed in this guide
must be followed throughout the module’s lifetime deployment. If you need additional information about the safe, proper use and
handling of MEMC photovoltaic module products, please contact MEMC.
2.0 PhoTovolTaIC Modules ProduCT Code
This guide is to be used for MEMC Silvantis
TM
72 cell photovoltaic (PV) module installation. Please refer to the following module
numbers before using the guide: P270AMA, P275AMA, P280AMA, P285AMA, P290AMA, P270ACA, P275ACA, P280ACA,
P285ACA, P290ACA
Modules with anti-reflective coating (AR coating or ARC): P280ACC, P285ACC, P290ACC, P295ACC, P300ACC, P305ACC,
P280AMC, P285AMC, P290AMC, P295AMC, P300AMC, P305AMC
3.0 Module overvIew
MEMC Silvantis Photovoltaic modules consist of a series of electrically interconnected crystalline silicon solar cells that are sealed
within a laminated sheet of tempered glass superstrate* and EVA/back-sheet substrate. These laminates are secured inside an
aluminum frame to provide rigidity and a means for attachment to mounting sub-structures. The frames should not be modified or
removed.
* Tempered glass may have AR coating.
•
Photovoltaic modules are designed and constructed for outdoor use. Do not submerge modules in water at any time.
•
The front and back of each module is labeled with a product bar code. Do not cover, remove or deface these labels. This may
be required for product identification.
•
Damage to the glass surface or the anti-reflective coating can impact the power output and overall efficiency of the system.
Scratches, handling marks, or any damage to the glass surface must be avoided.
•
For best performance and to avoid potential issues, keep the front side of the module clean and free of obstructions including
covers, tape, adhesives, paint and debris.
3.1 sTorage, unPaCkIng, and handlIng
•
Packaged modules must be stored in a dry and ventilated area.
•
Packaged modules must not be exposed to rain, snow, hail or other environmental conditions that may compromise the
packaging material and the modules.
•
Packaged modules must be on appropriate provided pallets and must not be stacked more than two pallet high for storage.
•
Once the modules are opened, store modules in a dry and ventilated room.
•
Modules should never be stored in a wet environment.
•
Upon unpacking, do not carry a module by its wires or junction box. Only carry a module by its frame with two or more
people.
•
Precaution should be taken to avoid damage to the glass surface with or without anti-reflective coating due to improper
handling during storage or unpacking.