Installation Manual: MEMC Silvantis 60 cell PV Modules
10 of 15
© Copyright 2012 MEMC Electronic Material
5.4 ELECTrICAL InSTALLATIon wArnIngS
• Installation and maintenance should be performed by qualified personnel only.
• use insulated tools during installation, troubleshooting and maintenance of photovoltaic modules.
• Installers should adhere to all applicable local, regional, and national codes and regulations when designing and constructing
the photovoltaic system.
• Photovoltaic modules produce dC electrical energy from light. when illuminated, each module can have a dC potential of
greater than 45v and should be handled with care.
• disconnecting modules under illumination may cause electrical arcing which may result in burns, fires, or other problems.
Modules connected in series should not be disconnected under illumination.
• Always use a wire management system that keeps wires and cables out of direct contact with edge surfaces which could cut
or damage the insulation. do not allow wires to rest on the ground or roof surface.
• The module junction box should not be opened or modified in any way in the field.
• Additional grounding holes may be added only with the express written consent of MEMC. new grounding holes must be
drilled using an approved drill jig, avoiding damage to the module glass, backsheet, or other module components.
• do not use mirrors, lenses, or other techniques to magnify or concentrate additional light on the module.
6.0 dISCLAIMEr of LIABILITy
The information in this manual is based on MEMC’s knowledge and experience and is believed to be accurate. however, all
information in this manual (without exception) including recommendations and specifications does not constitute a warranty,
expressed or implied. MEMC reserves the right to change the manual, the module, or specifications without prior notice.
The product warranty shall be voId if handling and installation of the product does not conform to MEMC’s written installation
instructions, or if the product has been reworked, repaired or otherwise modified in a manner not previously authorized by MEMC in
writing, or if the product is installed in an environment for which it was not designed. MEMC shall not be liable for special, indirect,
consequential, contingent or incidental damages related to or arising from the installation or use of the product by purchaser under
any circumstances.
MEMC assumes no responsibility for any product application or use which is beyond MEMC’s direct control. MEMC does not accept
responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in any way connected to such installation,
operation or maintenance of the product.
International Product Certifications:
IEC 61215, IEC61730, CE, uL 1730, and Safety Class II certifications ensure that MEMC solar products operate safely and comply with
global electrical, performance, reliability, and fire safety codes.
Certification
• IEC61215 certified by TÜv SÜd to ensure long-term operation in a variety of climates
• IEC61730 certified by TÜv SÜd to ensure electrical safety
• Stringent outgoing quality acceptance criteria benchmarked to industry standards
• uL1703 listed by CSA for Canada and uS
Environmental
AB8 (-50°C to +40°C)
fire resistance rating
Class C
MEMC Modules are certified by: