1.0 InTroduCTIon 

The purpose of this guide is to provide general information regarding the proper installation and handling of MEMC photovoltaic 
modules that serve residential, commercial, and industrial segments. System design, construction, and commissioning should be 
performed by qualified personnel only. 

To ensure system integrity, designers, installers and operators must meet all mechanical and electrical requirements for the system and 
its components. It is the responsibility of the system designer and installer to ensure that all codes and requirements are followed as 
well. 

Please review all the sections that pertain to proper installation of modules listed in this guide. The instructions detailed in this guide 
must be followed throughout the module’s lifetime deployment. If you need additional information about the safe, proper use and 
handling of MEMC photovoltaic module products, please contact MEMC. 

2.0 PhoTovoLTAIC ModuLES ProduCT CodE

This guide is to be used for MEMC Silvantis 60 cell photovoltaic (Pv) module installation. Please refer to the following module numbers 
before using the guide:  

Modules with tempered glass: MEMC-M235AMA, MEMC-M240AMA, MEMC-M245AMA, MEMC-M250AMA, MEMC-M255AMA 

Modules with anti-reflective coating (Ar coating or ArC): MEMC-M240AMC, MEMC-M245AMC, MEMC-M250AMC,  
MEMC-M255AMC, MEMC-M260AMC 

Modules with corner cap and tempered glass: MEMC-M240LMA, MEMC-M250LMA, MEMC-M260LMA  

Modules with corner cap and anti-reflective coating: MEMC-M240LMC, MEMC-M250LMC, MEMC-M260LMC

3.0 ModuLE ovErvIEw

MEMC Silvantis Photovoltaic modules consist of a series of electrically interconnected crystalline silicon solar cells that are sealed within 
a laminated sheet of tempered glass superstrate* and EvA/back-sheet substrate. These laminates are secured inside an aluminum 
frame to provide rigidity and a means for attachment to mounting sub-structures. The frames should not be modified or removed. 
* Tempered glass may have Ar coating.

•  Photovoltaic modules are designed and constructed for outdoor use. do not submerge modules in water at any time.
•  The front and back of each module is labeled with a product bar code. do not cover, remove or deface these labels. This may 

be required for product identification. 

•  damage to the glass surface or the anti-reflective coating can impact the power output and overall efficiency of the system. 

Scratches, handling marks, or any damage to the glass surface must be avoided. 

•  for best performance and to avoid potential issues, keep the front side of the module clean and free of obstructions including 

covers, tape, adhesives, paint and debris.

3.1 STorAgE, unPACkIng, And hAndLIng

• 

Packaged modules must be stored in a dry and ventilated area.    

• 

Packaged modules must not be exposed to rain, snow, hail or other environmental conditions that may compromise the 
packaging material and the modules.  

• 

Packaged modules must be on appropriate provided pallets and must not be stacked more than two pallet high for storage. 

• 

once the modules are opened, store modules in a dry and ventilated room.

• 

Modules should never be stored in a wet environment.

• 

upon unpacking, do not carry a module by its wires or junction box. only carry a module by its frame with two or more 
people.

• 

Precaution should be taken to avoid damage to the glass surface with or without anti-reflective coating due to improper 
handling during storage or unpacking. 

Summary of Contents for SunEdison MEMC-M235AMA

Page 1: ...A MEMC M240AMA MEMC M245AMA MEMC M250AMA MEMC M255AMA MEMC M240LMA MEMC M250LMA MEMC M260LMA MEMC M240AMC MEMC M245AMC MEMC M250AMC MEMC M255AMC MEMC M260AMC MEMC M240LMC MEMC M250LMC MEMC M260LMC Ins...

Page 2: ...tallation using shared rails M240 250 260LMA and M240 250 260LMC 7 4 5 Mechanical Installation Warnings 8 5 0 Electrical Installation 8 5 1 Planning and Design 8 5 2 Module Wiring 8 5 3 Grounding 9 5...

Page 3: ...vantis Photovoltaic modules consist of a series of electrically interconnected crystalline silicon solar cells that are sealed within a laminated sheet of tempered glass superstrate and EVA back sheet...

Page 4: ...cing which may result in burns fires or other problems Follow industry best practices when commissioning trouble shooting disconnecting or connecting a PV system Trouble shooting should include planni...

Page 5: ...ations For mounting locations for clamps or bolt for specified load please refer to Table on page 6 Each module should be mounted using four bolts through the mounting holes on the rear side of the mo...

Page 6: ...oles on each long side frame NOTE All modules are rated for a maximum rear load of 2400 Pa and a maximum front load of 5400 Pa when fixed to the mounting holes on the long side frames only Structural...

Page 7: ...260LMC SPECIFIC Toe in Modules using Corner Cap Feature System Overview Installation Step Illustration Toeing module into rail hook Module clip attachment Step 1 Place the bottom of the module on the...

Page 8: ...ately sized for the system design according to national regional and local codes Electrical characteristics are within plus or minus 5 of rated values for Isc Voc Impp and Vmpp Modules may operate und...

Page 9: ...um short circuit current of the system maximum operating temperatures and cable run lengths For field connections use at a minimum 12 AWG 4 mm2 wires insulated for a minimum of 85 C Use copper wire on...

Page 10: ...erience and is believed to be accurate However all information in this manual without exception including recommendations and specifications does not constitute a warranty expressed or implied MEMC re...

Page 11: ...ure C Maximum System Voltage V Limiting Reverse Current A Maximum Series Fuse Rating A 46 2 0 47 to 0 49 0 35 0 036 to 0 055 40 to 85 600 UL 1000 IEC 8 40 15 TEMPERATURE COEFFICIENTS AND PARAMETERS Mo...

Page 12: ...46 2 0 49 0 35 0 055 40 to 85 600 UL 1000 IEC 8 40 15 TEMPERATURE COEFFICIENTS AND PARAMETERS Module Dimensions mm Module Weight kg Cell Type Number of Cells Frame Material Corner Caps Glass mm 1 674...

Page 13: ...al 8 0 Appendix 8 1 Module dETAILS A 990 39 0 B 1 658 65 3 C 50 2 0 D 40 1 6 E 940 37 0 F 1 608 63 3 G 994 39 1 H 594 23 4 Module Dimensions Mounting Hole Spacing Dimension MM INCH Dimension MM INCH L...

Page 14: ...PV Modules 14 of 15 Copyright 2012 MEMC Electronic Material Front View Bolt Stack Details Center Mount Option 8 0 Appendix 8 1A Module dETAILS M240 250 260LMA and M240 250 260LMC SPECIFIC dimensions...

Page 15: ...tch printed version to documentation database MEMC Electronic Materials Inc 501 Pearl Drive City of O Fallon St Peters MO 63376 USA 1 636 474 5000 www sunedison com 8 0 AppendiX 8 3 Pre mounted Cables...

Reviews: