Installation Manual: MEMC Silvantis 60 cell PV Modules
6 of 15
© Copyright 2012 MEMC Electronic Material
REAR VIEW
FRONT VIEW
A
PErPEndICuLAr MounTIng
(CASES 1 & 2)
Structural rails running perpendicular to
the length of the module should be fixed
via bolts or clamps at the mounting holes
between each long side frame, or at the
holes on each short end frame.
noTE: All modules are rated for a
maximum rear load of 2400 Pa and a
maximum front load of 5400 Pa when
fixed to the side frames mounting holes
for CASE 1 or a front load of 2400 Pa
when fixed to the end frames mounting
holes for CASE 2.
PArALLEL MounTIng (CASE 3)
Structural rails running parallel to the length
of the module should be fixed via bolts or
clamps onLy at the mounting holes on
each long side frame.
noTE: All modules are rated for a
maximum rear load of 2400 Pa and a
maximum front load of 5400 Pa when
fixed to the mounting holes on the long
side frames only.
Structural rails running parallel to the
length of the module should nEvEr be
fixed to the end frames.
Maximum
rear Load:
2400 Pa or 50 psi
Maximum
front Load:
5400 Pa or 113 psi
Maximum
rear Load:
2400 Pa or 50 psi
Maximum
front Load:
5400 Pa or 113 psi
Maximum
rear Load:
2400 Pa or 50 psi
Maximum
front Load:
5400 Pa or 113 psi
REAR VIEW
FRONT VIEW
A
REAR VIEW
FRONT VIEW
B
BoLT MounT
LoCATIonS
CLAMP MounT
LoCATIonS
MounTIng ConfIgurATIonS
LoAd PArAMETErS
C
ASE
1
C
ASE
2
C
ASE
3
Module Color Code: Mounting hole Location
Module rail
Clamp Mount range
Clamp mount
allowable range
Clamp mount
allowable range
A – 382 mm
B – 248 mm
Clamp mount allowable range:
Clamp mount
allowable range
4.2A MounTIng ConfIgurATIonS uSIng BoLT MounT or CLAMP MounT oPTIonS