NOTE FOR THE REPLACING OF MEMORY IC
C4-1
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
INI
DATA
00
0A
ADDRESS
INI
01
02
INI
02
00
INI
03
64
INI
04
64
INI
05
4A
INI
06
INI
07
INI
08
INI
09
INI
0A
INI
0B
INI
0C
INI
0E
00
INI
0F
8C
INI
10
68
INI
11
5C
INI
12
53
INI
0D
0B
26
85
53
0C
08
0C
0A
INI
INI
INI
INI
INI
DATA
00
00
00
00
00
00
Table 1
13
14
15
16
17
18
ADDRESS
INI
INI
19
00
1.
2.
Turn on the POWER.
While pressing the CH UP key on the set, press the FF key on the set for more than 2 seconds.
ADDRESS and DATA will appear on TV Monitor as FIG 1.
ADDRESS
DATA
3.
4.
5.
6.
7.
8.
The unit will now have the correct DATA for the new MEMORY IC.
Fig. 1
ADDRESS is now selected and should "blink". Using the FF or REW button on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using FF or REW button until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.