SDM-9600 with SDM-9606 Blades Hardware Installation Guide
5-18
Memotec Inc.
5.9.5
E1/T1 Cables
You must provide an RJ-48 cable for each E1/T1 connection. Select a standard unshielded
twisted pair (UTP) male-male cable with RJ-48 connectors,
at least 26AWG, or 0.4mm
.
NOTE:
Install a ferrite on each cable that connects to an E1/T1 port when installed
and operated in the European Union: Steward ferrite 28A2024-0A0, Part No.
332-0003-000.
The following table describes the RJ-48 pinout required for E1/T1 ports.
NOTE:
An E1/T1 interface is hard-strapped as
NT
by default for connection to
TE
equipment. Use a crossover cable where
TE
mode is required for connection
to
NT
equipment.
TE Mode
NT Mode
Pin No.
Signal
Pin No.
Signal
1
Receive (+)
1
Transmit
2
Receive (-)
2
Transmit
3
(not used)
3
(not used)
4
Transmit (+)
4
Receive
5
Transmit (-)
5
Receive
6
(not used)
6
(not used)
7
(not used)
7
(not used)
8
(not used)
8
(not used)
Table 5-10: RJ-48 pinout for E1/T1 ports
Summary of Contents for NetPerformer SDM-9600
Page 1: ...NetPerformer SDM 9600 with SDM 9606 Blades Hardware Installation Guide...
Page 6: ...Memotec Inc 7 4 Network Management and Security 7 5 Index 7...
Page 8: ...Memotec Inc...
Page 10: ...Memotec Inc...
Page 11: ...1 Memotec Inc 1 1 Preface...
Page 22: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 1 12 Memotec Inc...
Page 23: ...2 Memotec Inc 2 1 Compliance Information...
Page 34: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 2 12 Memotec Inc...
Page 35: ...3 Memotec Inc 3 1 Unpacking the SDM 9600...
Page 39: ...4 Memotec Inc 4 1 Hardware Installation...
Page 63: ...5 Memotec Inc 5 1 Product Description...
Page 81: ...6 Memotec Inc 6 1 Troubleshooting Tips...
Page 84: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 6 4 Memotec Inc...
Page 85: ...7 Memotec Inc 7 1 Networking Features...
Page 90: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 7 6 Memotec Inc...
Page 93: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide Index 9...