SDM-9600 with SDM-9606 Blades Hardware Installation Guide
6-2
Memotec Inc.
6.1 Symptoms, Problems, and Solutions
Symptom
Possible Problem
Solution
Unit does not start, with:
OOS
LED off
ST
LED off
ALM
LED off
No power to unit
Make sure the power harness is properly attached to
the power inlet on the uni.t, and to the DC power
supply
Check power harness and replace immediately if
damaged.
Make sure the DC power inlet has power.
Unit does not start, with:
OOS
LED amber
ST
LED any state
ALM
LED any state
Critical error. Unit
may be faulty
Contact Technical Support for assistance (see
“Technical Support” on page 1-8
).
Unit starts, with:
OOS
LED green
ST
LED any state
ALM
LED red
A software reset
occurred
Enter
DA
at the console command line to view the
alarms.
If a
soft start (rst)
alarm has been logged with the
notation
M=xx A=xx D=xx
, enter
ER
to dump the
Exit Record. Send to Technical Support.
Enter
CE
(Clear ERR/DIAG LED) to turn the
ALM
LED off.
Unit starts, with an alarm
message of the type:
An error has occurred
(0x00100000 0xC0000002),
please call the technical
support.
A hardware error
occurred
Enter
DA
at the console command line to view the
alarms.
Contact Technical Support and provide alarm codes.
Console connection does not
work
Incorrect cable
connection
Make sure you are using the factory-supplied
console cable and RJ-45 to DB-9 terminal adaptor
Make sure the cable is properly plugged into the
CSL
port and the console terminal COM port
HyperTerminal
communications
program
Change
Emulation
parameter setting from
Auto
detect
to
ANSI
(see
“Notice Concerning
HyperTerminal Connections” on page 8-1
).
Incorrect modem
setting
Set the modem to ignore DTR by executing the AT
command
at&d0
Set the modem to Auto Answer mode: execute
ats0=1
Summary of Contents for NetPerformer SDM-9600
Page 1: ...NetPerformer SDM 9600 with SDM 9606 Blades Hardware Installation Guide...
Page 6: ...Memotec Inc 7 4 Network Management and Security 7 5 Index 7...
Page 8: ...Memotec Inc...
Page 10: ...Memotec Inc...
Page 11: ...1 Memotec Inc 1 1 Preface...
Page 22: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 1 12 Memotec Inc...
Page 23: ...2 Memotec Inc 2 1 Compliance Information...
Page 34: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 2 12 Memotec Inc...
Page 35: ...3 Memotec Inc 3 1 Unpacking the SDM 9600...
Page 39: ...4 Memotec Inc 4 1 Hardware Installation...
Page 63: ...5 Memotec Inc 5 1 Product Description...
Page 81: ...6 Memotec Inc 6 1 Troubleshooting Tips...
Page 84: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 6 4 Memotec Inc...
Page 85: ...7 Memotec Inc 7 1 Networking Features...
Page 90: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 7 6 Memotec Inc...
Page 93: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide Index 9...