12
Item #
NAME
DESCRIPTION
1
USB Port
Used to update your grill, see the “Updating Controller Software” section of the
main manual for information.
2
Meat Probe Wiring
This terminal is used to connect the meat probes to the controller.
3
120/240 Select Jumper
Used when changing the input voltage to the controller, see “120v to 240v
Conversion” section of the main manual for information.
4
AC Load Wire from Filter to
Controller
Carries AC voltage from the filter to the control board, load wire.
5
AC Neutral Wire from Filter to
Controller
Carries AC voltage from the filter to the control board, neutral wire.
6
Filter
Reduces electrical feedback. Line = Outlet Side, Load = Grill Side. L1 = Load L2=
Neutral
7
AC Neutral and Load from IEC to
Filter
A two wire component which has a ferrite choke to eliminate input electrical
disturbances from the grid. Load and Neutral wires.
8
IEC Plug
The same plug terminal used to attach your power cord to your grill. Top down view.
9
Ethernet Cable
Used to connect your grill controller to the Wi-Fi card in the back of the grill.
10
Grounding Wire
In the event your grill experiences a short, the grounding wire will send the voltage
to the 3
rd
prong of a standard AC outlet.
11
AC Component Wiring
This large plastic connector carries all voltage used for AC components in the grill.
See “Component Wiring Diagram” for a description of all wires in this connector.
12
RTD Wiring (DC)
This small plastic connector carries DC voltage to the RTD.
13
Controller Box Ethernet Cable
Gland
This gland is a weather tight pass-through for the Ethernet cable into the back of
the controller box.
14
Controller Box Plug
This plug is a weather tight quick disconnect for the main wiring harness which
carries all AC,DC, and Ground wires to the grill’s components.
MEMPHIS ELITE BUILT-IN
CONTROLLER BOX WIRING
DIAGRAM
LOAD
NEUTRAL
GROUND