background image

User Manual

 

MH70S

Rugged Data Storage & NAS Computer with Intel Core i3/i5/i7

Modular Embedded System for Industrial Automation & Railway Transport

2019-10-24

20MH70S00 E3

Summary of Contents for MH70S

Page 1: ...User Manual MH70S Rugged Data Storage NAS Computer with Intel Core i3 i5 i7 Modular Embedded System for Industrial Automation Railway Transport 2019 10 24 20MH70S00 E3...

Page 2: ...ing the MH70S 22 2 4 1 Safety Instructions for Mounting 22 2 4 2 Wall Mounting the MH70S 23 2 4 3 Mounting the MH70S in a 19 Rack 25 2 5 Connecting and Starting 29 2 5 1 Safety Instructions for Connec...

Page 3: ...oard 42 Figures Figure 1 MH70S configuration example maximum configuration 12 Figure 2 Bottom and top of system not covered airflow from bottom to top 16 Figure 3 Product label BTO model 17 Figure 4 P...

Page 4: ...possible functions For a detailed description of the functionality of the individual boards please refer to the boards user manuals History MH70S product page with up to date information and downloads...

Page 5: ...t links directly to the Internet When no globe icon is present the hyperlink links to specific information within this document Italics Folder file and function names are printed in italics Comment Co...

Page 6: ...notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these product...

Page 7: ...us a so called downstream user in terms of REACH The products MEN supplies are solely non chemical goods Moreover and under normal and reasonably foreseeable circumstances of application the goods sup...

Page 8: ...e MEN products for any unintended or unauthorized application the customer shall indemnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmless against all claims...

Page 9: ...ro Elektronik SAS 18 rue Ren Cassin ZA de la Ch telaine 74240 Gaillard Phone 33 450 955 312 info men de www men de info men france fr www men france fr USA MEN Micro Inc 860 Penllyn Blue Bell Pike Blu...

Page 10: ...e implemented For robust and safe operation the HDD carriers can be configured in RAID 0 1 or 5 while the carriers themselves have their own internal RAID 0 1 and JBOD hardware configuration possibili...

Page 11: ...recorder or as an NAS system The system can be used with the open source OpenMediaVault operating system The operating system OpenMediaVault is based on the Linux distribution Debian and offers a com...

Page 12: ...6 Slot PSU CPU I O I O I O I O I O 1 I O STATUS DC DC 120W PU20 CompactPCI Serial EJECT HP AC2 AC1 LOC PWR CompactPCI Serial EJECT HP AC2 AC1 LOC PWR CompactPCI Serial EJECT HP AC2 AC1 LOC PWR Compact...

Page 13: ...ls fan provides status LEDs and power button Power Supply PSU 3U Configurable yes Possible Configurations 120 W 3U 6 HP PSU wide range input 24 to 110 V DC 24 V DC nom output 12 V 5 V 3 3 V DC 40 C to...

Page 14: ...ctors at front 0 C to 60 C 4 1000Base T Ethernet interfaces 4 M12 connectors at front 40 C to 85 C conformal coating Ethernet Switch Functionality CPCI Serial 3U Board Configurable yes Possible in Com...

Page 15: ...formation video distribution systems with PoE and fans Temperature range storage 40 C to 85 C Cooling concept Air cooled forced convection with fan tray at system bottom Relative humidity operation ac...

Page 16: ...ion Natural convection for fanless operation Not possible with MH70S Forced convection using two fans in a fan tray at the bottom of the housing Required with some of the CPUs available Figure 2 Botto...

Page 17: ...duct family and model To be complete it must have 9 characters Revision number Indicates the design revision of the product Serial number Unique identification assigned during production Ordering key...

Page 18: ...r dangerous voltage and can cause fire Damaged equipment has unpredictable behavior and characteristics Prevent damaged equipment from being installed and put into operation Mark the damaged equipment...

Page 19: ...system Remove the carrier board from the system If there are already HDDs SSDs installed Installing the first HDD SSD Place the first HDD SSD in the slot close to the front panel on the carrier board...

Page 20: ...o the front panel with a M3x6 TX8 screw Apply thread locker to ensure the screws are not loosened by vibrations Installing the second HDD SSD Place the second HDD SSD in the slot close to the rear con...

Page 21: ...the bottom side with two M3x8 TX8 socket head screws position highlighted in red in the following drawing Secure the HDD SSD additionally by fixing it to the guide rail with a M3x6 TX8 screw Apply thr...

Page 22: ...s specified in the Technical Data Leave enough space to the sides of the system that are needed for cooling to enable the required airflow as specified in chapter Cooling Concept Do not cover openings...

Page 23: ...ounting brackets have to be moved to the rear of the system The following steps are necessary To remove the mounting bracket loosen the two screws securing the mounting bracket After removing the moun...

Page 24: ...t with the M4x12 TX20 countersink head screws included in the delivery Repeat the above process for the mounting bracket on the other side of the system Apply thread locker to all mounting screws to e...

Page 25: ...racket at the right side of one MH70S and on the left side of the other MH70S Place the front and rear bonding brackets supplied with the bonding kit as shown in the following illustration Secure the...

Page 26: ...wo MH70S systems next to each other and slide them together so that the screw holes in the bonding kit brackets are aligned as in the following picture Moun ng screw Moun ng screw Side Panel Front pan...

Page 27: ...Getting Started 20MH70S00 E3 2019 10 24 Page 27 Connect the systems using four M3x8 countersink head screws two screws at the front and two at the back Bonding kit brackets M3x8 countersink head screw...

Page 28: ...the system The following steps are necessary Remove the mounting bracket at the right side of the MH70S Screw the kit to the right side of the MH70S using four M4x12 screws Apply thread locker to all...

Page 29: ...to identify risks and avoid potential hazards when working with these products systems Any power input must be protected by an external fuse as defined in chapter Connecting the Power Supply Implemen...

Page 30: ...onfiguration and coding labeling on the system for the exact config uration and pin assignment Figure 4 Power configuration and coding labeling example Plug an external power supply to the power inlet...

Page 31: ...cription on how to install driver software please refer to the respective documentation of the software package to be installed See Chapter 3 1 1 Power Button on page 32 See the MEN website for the CP...

Page 32: ...ICON plug e g Phoenix Contact IC 2 5 3 STGF 5 08 Mating 3 pin COMBICON receptacle e g Phoenix Contact FKCT 2 5 3 STF 5 08 1 Vin 2 PE 3 Vin Signal Direction Function PE Shield Vin Ground Vin in Power i...

Page 33: ...ow In normal operation you do not have to make any changes in the configuration 3 2 1 Control Panel LEDs The status of the MH70S is signalled using LEDs at the front of the system The following table...

Page 34: ...SU detects a problem in the system power supply Off all other states Fan Fail Red On fan failure is detected Off all other states Temp Fail Red Blinking system temperature too cold On system temperatu...

Page 35: ...C DC 120W PU20 2 3 4 5 6 Slot PSU CPU I O I O I O I O I O 1 I O STATUS DC DC 120W PU20 CompactPCI Serial EJECT HP AC2 AC1 LOC PWR CompactPCI Serial EJECT HP AC2 AC1 LOC PWR CompactPCI Serial EJECT HP...

Page 36: ...eral I O 1 G304 Smart Managed 4 Port Industrial Ethernet Switch with PoE G211 Quad Gigabit Ethernet Interface Board G212 Wireless Network Board for 2 PCIe and 2 SIM Cards2 G227 Wireless Network Board...

Page 37: ...sted Platform Module TPM A trusted platform module for authenticating the hardware to ensure platform integrity is available on the MH70S The TPM module is compliant to the TPM v1 2 specification Proc...

Page 38: ...10 HDDs installed 5 transparent for CPU RAID levels 0 1 and 5 with hot spare disc on system level depends on operating system support RAID levels 0 1 and JBOD on one G503 carrier Hot swap support Auto...

Page 39: ...o the PCI Express Mini Card Standard 4 Reverse SMA Antenna connectors 2 micro SIM card holders To get access to a mobile phone network you need a SIM card subscriber identity module and a contract wit...

Page 40: ...ystem and the labels are not damaged The MH70S is equipped with a lithium battery There is a danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type Ma...

Page 41: ...lowing components use fuses PU20 3U 6 HP PSU Wide Range Power Supply Unit for Railway Systems 24 to 110 VDC 120 W www men de products pu20 PU21 3U 6 HP PSU Wide Range Power Supply Unit for Railway Sys...

Page 42: ...el is smoothly aligned to the neighboring front panels If the board has an ejector Turn the ejector up until it clicks into place Fasten the fixing screws tightening torque 0 3 Nm 4 4 2 Removing a Plu...

Page 43: ...gn the handle with the fixing screws turn the handle so it aligns with the front panel then pull the assembly out of the slot If you do not have a board removal handle Firmly grip both fixing screws o...

Reviews: