background image

 

 
 

 

 

 
 

 

 

MEND Wellness

TM

 (IS02LCDs) 

User’s Manual 

 
 

Ver 1.8 2021.9.17 

Summary of Contents for IS02LCDs

Page 1: ...1 MEND WellnessTM IS02LCDs User s Manual Ver 1 8 2021 9 17...

Page 2: ...E Sunnyside Road Ste F40 Clackamas OR 97015 Phone 503 594 4045 Fax 503 594 4046 2021 MEND Tech LLC All rights reserved MEND Technology and the logo are the trademarks of MEND Tech LLC Trademarks or re...

Page 3: ...to a protocol 14 To see details of a protocol 14 Run a Therapy Protocol HOLD the timer 15 Pause the Therapy Protocol SKIP a frequency pair 15 Stop the Therapy Protocol 15 Turn on the Back Light 15 Tur...

Page 4: ...eping 20 To change the OUTPUT Drive 20 About 20 To go to About 20 Version 20 Battery Status 20 Low Battery Indication 21 Disclaimer 21 Maintenance Troubleshooting 21 Pre Use Inspection 21 Sanitizing 2...

Page 5: ...nt selection Warnings and Contraindications Microcurrent stimulation should not be used on patients whose pain syndromes are not diagnosed and etiology is not established If another electrode is used...

Page 6: ...ns are potential adverse reactions Cleaning and hydrating the skin are usually valid methods to reduce the skin irritation or electrode burns If gloves or cloth or garment are used as electrodes these...

Page 7: ...nder section 510 K of the Federal Food Drug and Cosmetic Act as a device substantially equivalent to a device in commerce Inspirstar Inc and MEND Technology expressly disclaim any claim that the Produ...

Page 8: ...ON to turn on the device or to start the selected protocol Key PAUSE to pause the running of the current protocol Use key START to resume the running Key STOP to stop the protocol in running or to tu...

Page 9: ...nly not to supply power to the MEND Wellness device The MEND Wellness only operates with battery power supply Equipment that is connected to the Micro USB port interfaces must be certified according t...

Page 10: ...Mapping of Output Ports to Wire Connectors Accessories The MEND device can be used with various accessories that can be purchased individually For example gloves electrodes push pin leads conductive s...

Page 11: ...panel of the MEND WellnessTM device Install Batteries The MEND WellnessTM device uses two alkaline batteries in size AA Remove the batteries when the device is not going to be used for more than one m...

Page 12: ...WellnessTM after use If you want to unbutton the electrode wires from the gloves hold the button base on the gloves instead of holding the fiber part of the gloves to avoid damage to the gloves DO NO...

Page 13: ...the top of the list Use History Protocols to check the therapy history and also to select a protocol to run again Note the history will show the exact usage so you may see the same protocol multiple t...

Page 14: ...ys to change the value Use the LEFT arrow to move to the tens digit and use UP and DOWN to change the value Use the RIGHT arrow to move to the ones digit Press SET again when done Alternatively press...

Page 15: ...used no current is running The maximum time for a PAUSE is 30 minutes Stop the Therapy Protocol At any time during a protocol you can press the STOP key to stop running a therapy protocol Turn on the...

Page 16: ...16 Turn power off Depending on which screen you are on continue to press the STOP OFF key to turn off the MEND WellnessTM The unit will power off automatically if the unit is not in use for 60 seconds...

Page 17: ...firmly into the jacks and your pins are plugged into the conductive material The common problems are loose plugs plugs are not inserted the button or push pin is not inserted into gloves or electrode...

Page 18: ...or stop of the protocol press both the LEFT and RIGHT keys simultaneously A lock icon will appear to indicate the keypad is locked Press the LEFT and RIGHT keys simultaneously to unlock The new value...

Page 19: ...bove steps for other slots Remove a protocol from batch select the batch slot and press and hold STOP key for 2 seconds until the slot is changed to empty You can have empty slot between protocols in...

Page 20: ...field use UP DOWN to change the value Press SET to enter the new value To change the Output Drive press the SET key a couple of times to go to 3 Output Drive Use UP DOWN arrows to change the value be...

Page 21: ...ou see the Low Battery message Disclaimer shows the disclaimer for the device Machine is approved for pain use only Names descriptions are solely to assist in most appropriate protocol selection No cl...

Page 22: ...e the device with non dripping cotton balls or sanitizing wipes with germicide or alcohol It would be safe to wipe the faceplate keypad display LCD screen and the whole enclosure if the wiper does not...

Page 23: ...rm the Pre Use Inspection Contact your health care practitioner or MEND Technology if the problem persists No sensation of current This is normal for the low current intensity Treatment is not effecti...

Page 24: ...to 18 hours for each frequency pair Timer Accuracy 0 2 Protocols Number of Protocols Up to 99 programmable Frequency Pairs Up to 7000 frequency pairs limited by memory size and complexity of the prot...

Page 25: ...F1 Frequency 2 F2 Current Intensity I Time T Waveform etc Please refer to Waveform Description of this document for detailed explanation of all parameters F1 F2 Current Intensity Period K0 K3 Polarity...

Page 26: ...od current ramps down from the peak current intensity I to 0 A Period Period of the modulated pulse The pulse can be modulated by the carrier frequency F The period is programmable from 4 ms to 60000...

Page 27: ...27...

Page 28: ...logy 10117 SE Sunnyside Rd Suite F40 Clackamas OR 97015 Toll free 855 445 3971 Direct 503 594 4045 Fax 503 594 4046 www mendtechnology com support mendtechnology com Copyright 2021 MEND Tech LLC All r...

Reviews: