T

hese instructions cover the basic principles to ensure the satisfactory installation of the Mendip Stoves

Ltd :-  Churchill , Loxton  and Sqabox models, although detail may need slight modification to suit particular
local site conditions.
In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and
other specifications or regulations as they affect the installation of the stove.
It  should  be  noted  that  the  Building  Regulations  requirements  may  be  met  by  adopting  the  relevant
recommendations given in British Standards BS 8303, BS EN 15287 as an alternative means to achieve an
equivalent level of performance to that obtained following the guidance given in Approved Document J.

HEALTH AND SAFETY PRECAUTIONS

—----------------------------------------------------------------------------------------------------

INFORMATION FOR THE USER, INSTALLER AND SERVICE ENGINEER

—----------------------------------------------------------------------------------------------------

Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are
met.

Handling

Adequate facilities must be available for loading, unloading and site handling.

Fire Cement

Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact
wash immediately with plenty of water.

PREPARATORY WORK AND SAFETY CHECKS

IMPORTANT WARNING

This stove must not be installed into a chimney that serves any other heating appliance. There must not be an extractor

fan fitted in the same room as the stove because this can cause the stove to emit fumes into the room.

Asbestos

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the coarse of installation then please

seek specialist guidance and use appropriate protective equipment.

Metal Parts

When installing or servicing this stove care should be taken to avoid the possibility of personal injury.

CO Alarms:-

Building regulations require that when ever a new or replacement fixed solid fuel or wood/biomass appliance is installed
in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance. Further guidance on the
installation of the carbon monoxide alarm is available in BS EN 50292:2002 and from the alarm manufacturer’s
instructions.

Provision of an alarm must not be considered a substitute for either installing the appliance correctly or

ensuring regular servicing and maintenance of the appliance and chimney system.

Stove paint Aerosols
Paint aerosols are flammable and therefore dangerous to use around a lit stove. Be sure to allow  aerosols spray paints
to dry  and ventilate the room well  before lighting the stove. The use of any aerosol around lit stove is dangerous and
care must be take in handling aerosols.

Summary of Contents for Churchill 10

Page 1: ...1 OPERATION AND INSTALLATION MANUAL Multi fuel and SE models Loxton 3 5 6 8 10 Churchill 5 6 8 10 Sqabox unO duO...

Page 2: ...URCHILL 6 PEDESTAL CHURCHILL 8 kW CHURCHILL 8 PEDESTAL CHURCHILL 10 kW CHURCHILL 10 PEDESTAL CHURCHILL 6 kW convection CHURCHILL 6 PEDESTAL convection CHURCHILL 8 kW convection CHURCHILL 8 PEDESTAL co...

Page 3: ...CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove because this c...

Page 4: ...C 12 pa Loxton 8 5 8 7 1 g sec 291 332deg C 12 pa Loxton 10 6 9g sec 325deg C 12 pa Churchill 5 4 3 4 7 g sec 231 221deg C 12 pa Churchill 6 4 3 4 7 g sec 231 221deg C 12 pa Churchill 8 5 8 7 1 g sec...

Page 5: ...fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and...

Page 6: ...ush Only Use a damp cloth on external surfaces Over time the glass may become dirty clean with a damp cloth and polish off with damp cloth If the stove has not been used for some time the flue should...

Page 7: ...construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or on the hear...

Page 8: ...plate This collar allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney Commissioning and handover Ensure loose parts are fitted in accordance with the...

Page 9: ...couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened the smell will disappear This stove is...

Page 10: ...for smoke control areas see page 4 alterations should not be attempted Mendip smoke control stoves should not be burnt with the door left open The refuelling procedure allow the newly charged fuel to...

Page 11: ...ood Newly cut wood should be stacked and air dried under cover for two years before being used as firewood Do not burn liquid fuels drift wood finished sawn wood pallet wood chipboard plywood varnishe...

Page 12: ...r hand from possible heat The handle has push pull motion as shown above When shutting the door push the door closed and push handle firmly until the door latches PARTS Always use the operating tools...

Page 13: ...l collect behind it and this must be cleaned out Check the quality of all insulated panels and replace any which are damaged or cracked replace stove door rope cord in the door Check glass is correctl...

Page 14: ...fails to heat fully a The firewood may be too wet b the intake of secondary air may be insufficient 5 Smoke or odour a Weak chimney draft b check for blockages in the flue pipe chimney c check the he...

Page 15: ...15...

Page 16: ...ve Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Mendip Stoves Ltd 2012 ver 3...

Reviews: