Dropping Flex Vent Liners
Installing Flex Liners
1.
Measure the chimney height from the top of the chimney (or the existing flue liner) to a point 12" (300 mm) above the
floor of the fireplace hearth. It may be necessary to drop a rope and measure the rope itself. Be sure to allow for all
offsets in existing chimney. Cut the 4" and 3” diameter flex liners to this measured length.
2.
Attach a sheet metal strap loop to the flex end of the liner(s) and tie a rope to it. Two installers should proceed to the
roof and drop the rope (with weight on the end to make sure it goes all the way down) and insert the 4” and 3” liners
past the flexible portion, into the existing chimney.
3.
One installer should then return to the fireplace opening and pull the rope to guide the liner(s) into place through the
smoke shelf and the damper opening to a point 12" (300 mm) above the fireplace hearth. The person below should
wear leather gloves and Safety Glasses during this process to avoid being cut and to safeguard eyes from flying debris.