MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM
As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is
important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and
qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed.
HOME OWNER: ________________________________
DEALER: _________________________________________________
ADDRESS: _____________________________________
ADDRESS: ________________________________________________
CITY/STATE/ZIP: _______________________________
CITY/STATE/ZIP: __________________________________________
SIGNATURE: ___________________________________
PHONE: __________________________________________________
MODEL #: SDV40 SERIAL #: __________________
DATE INSTALLED: _________________________________________
GAS ________ NAT or _________ L.P.
Mendota Fireplace Inserts are sophisticated, hi-tech gas appliances. All installation and operating instructions must be carefully
followed. The DXV fireplace must be installed and serviced by a qualified Mendota approved service person.
REF:
MENDOTA GAS FREESTANDING STOVE
APPROVED VENT PIPES AND VENT CAP INSTALLED - Per Manual and manufacturer's specifications
CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES - Per pipe manufacturer's specifications
INSTALL PROPER SIZE GAS LINES - CHECK FOR GAS LEAKS - Per Manual
CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD - Per Manual
a. 3.5 Inches Water Column Maximum - Nat. Gas
b. 10.5 Inches Water Column Maximum - L.P. Gas
TAKE COMBUSTION SYSTEM MILLIVOLT READINGS [ See Manual Pg. 26]
a. Pilot only - [Minimum Millivolts 325]
Reading: _______________________
b. Main burner operating - [Minimum Millivolts 100]
Reading: _______________________
CYCLE BURNERS ON/OFF FOR PROMPT IGNITION - Per "LIGHTING INSTRUCTIONS"
Burner must light IMMEDIATELY - Flame must travel promptly around "curve" & light burner.
INSTALL LOGS AND ADJUST FLAME - Per Manual
Proper pilot flame impingement on thermopile & burner - Air shutter opening: 1/8" - 1/4" Nat. Gas - 1/2" LP
BRIEF OWNER ON OPERATION AND MAINTENANCE OF UNIT
Light Pilot
Operate Burner Explain blower "delay" operation
WARRANTY REGISTRATION
Your Name _______________________________________________________________________
Address __________________________________________________________________________
City ________________________________________ State ______ Zip ______________________
Dealer (Place of Purchase) ___________________________________________________________
City ________________________________________ State ______ Zip ______________________
Date of Purchase _______________________ Serial Number _______________________________
Purchaser's Signature________________________________________________________________
ÿ
MENDOTA FREESTANDING STOVE, SDV40
CUT OUT PAGE AND MAIL TO: JOHNSON GAS APPLIANCE CO., 520 E AVE. N.W. , CEDAR RAPIDS, IOWA 52405
3
0
Summary of Contents for MEDALLION
Page 21: ...Log Fire View Figure 9 Log Module 2 0...
Page 33: ...NOTES NOTES 3 2...