Operating Instructions - CPC8000
4.3 General Specifcations
Size
See
Weight
~49 lbs (~22.2 kg) with all internal options.
Mounting
Standard: desk top case with bezel and handle.
Optional: 19” rackmount kit.
Power input requirements
100 – 120 VAC / 200 – 240 VAC, 50 – 60 Hz
Energy Consumption
Max 140 VA
Pneumatic interfaces
7/16-20 female SAE threaded ports for Measure/Control, Exhaust, Vent, Reference,
and Supply. Hose barb for barometer. Other fttings per customer request.
Particle flters
The instrument has 40-micron flters on all pressure ports through the manifold.
The barometer has no flters
Pneumatic overpressure
protection
Each sensor is protected with pneumatic relief valves set 10-25% over the maximum transducer
pressure.
Compensated temp. range
15 to 45 °C
Operating temp. range
0 to 50 °C
Storage temp. range
0 to 70 °C
Local user interfaces
9” Color LCD display with glass capacitive touch screen
Remote user interface
RS-232 (null modem cable not required), Ethernet, USB, and IEEE 488.2
Warm-up
15 minutes to rated accuracy
Reading rate
32+ readings/second, unique readings/second is sensor dependent.
Transducer Response time < .33 seconds after a 0-FS step
Orientation efects (tilt)
Negligible, can be removed with re-zeroing. (calibrate and operate in a horizontal position)
Shock / vibration
2 G’s Max
Pressure media capability
Clean, dry, non-corrosive, non-combustible, non oxidizing gases. No oxygen.
Metals in contact with media 6000 series Aluminum, 316 SS, Brass
Non-metals in contact
with media
Tefon, Urethane, Silicone, RTV, Silicone grease, PVC, Epoxy, Ceramics
Operating environment
0-95% RH, non-condensing
CE-mark
Conformity certifcate. Complies with EN50081, EN50082, and EN61010-1.
Calibration certifcate
Includes calibration certifcate(s). The Mensor calibration laboratory is accredited in accordance
with the recognized Internal Standard ISO/IEC 17025:2005 and also meets the requirements
of ANSI/NCSL Z540-1-1994. Accreditation is by the American Association for Laboratory
Accreditation (A2LA).
Warranty
Two year warranty
Options
0.008% IS-
33
sensor option
Transport/travel case
Barometric reference transducer
Spare Primary, Secondary or Tertiary transducer
19” rackmount kit
WARNING! This is class A equipment for emissions and is intended for use in industrial
environments. In other environments, e.g. residential or commercial installations, it can
interfere with other equipment under certain conditions. In such circumstances the operator
is expected to take the appropriate measures.
Summary of Contents for CPC8000
Page 6: ...High End Pressure Controller CPC8000 6 Operating Instructions CPC8000 NOTES ...
Page 10: ...High End Pressure Controller CPC8000 10 Operating Instructions CPC8000 NOTES ...
Page 24: ...High End Pressure Controller CPC8000 24 Operating Instructions CPC8000 NOTES ...
Page 84: ...High End Pressure Controller CPC8000 84 Operating Instructions CPC8000 Notes ...
Page 112: ...High End Pressure Controller CPC8000 Operating Instructions CPC8000 113 NOTES ...