45
WIKA operating instructions hydraulic high pressure controller model CPC8000-H
PN 0018708001B 11/2020 EN
EN
6. Operation
Figure 6.4.2.4 Remote Settings
6.4.2.4.1
Command Set
The Command Set button within the Remote application provides a place for the operator to choose which command set that will
be used within remote communication software to control and query the CPC8000-H. When the Command Set button is selected,
any of the listed command sets available will appear on the right side of the screen (Figure 6.4.2.4). The active command
set will be highlighted blue, changing to a different command set will allow the CPC8000-H to automatically switch to the new
communication format.
6.4.2.4.2
Termination Character
The Termination Character button within the Remote application provides an option for the user to select the desired termination
character in the output string of the instrument(Figure 6.4.2.4.2). In most cases, this can be set to "default" where the instrument
automatically chooses the termination character based on the selected command set. The options for termination characters are
as follows:
• CRLF : Carraige Return Line Feed
• CR : Carraige Return
• LF : Line Feed
• EOI : End of Input
Figure 6.4.2.4.2 Termination Character