III. FAULTS AND CAUSES.
Fault
Type
Description
Possible origins
Person
intervening
Power cut
Baker
Emergency stop engaged
Baker
Thermal relay disconnected
Baker
Power
Motor does not work
Motor out of service
Technician
Power
Dough proofer motor
protection disconnected
permanently
Adjustment of thermal relay
Baker or
technician
Band too tight
Technician
Power
Belt motor protection
(unloading or transfer)
disconnected permanently
Adjustment of thermal relay
Baker or
technician
The Mécaform chain does not
turn in the right direction
Technician
Drive pinions misaligned or
unlocked
Technician
Quick disconnect fastener of
the gutter chain is not
properly locked
Technician
Operation
Abnormal noise of Mécaform
VE
Chains wrongly tightened
(drive, gutter)
Baker or
technician
Operation
The proofer does not stop at
the right place
Proofer stroke end wrongly
adjusted
Technician
Operation
The Mécaform does not
rotate when loaded
The drive motor torque
switch must be readjusted
(by ¼ turn)
Technician
The proofer chain does not
turn in the appropriate
direction
Technician
Operation
Mécaform Ve is blocked
Faulty frame
Technician
or baker
Moulder misplaced
Technician
or baker
Operation
The dough roll does not fall
properly into the moulder
Belt position is not properly
set
Technician
or baker
Operation
The V’s are not well closed
Adjustment of the stroke end
position
Technician
Operation
Belts that countersink
Adjustment of the belt
tightness
Technician