background image

20-07315-UK

-02

8

CLEANING & CARE

•   The chair should be wiped down and kept clean from dust and dirt . 
•   The chair should be washed using a disinfectant with PH 7–12 (concentrated), with the exception of the padding . 
•   Plush upholstery has to be washed with a foam wash:  
 

 

1 . Remove loose dirt, crumbs and the like .  

 

 

2 . Apply a thin layer of foam and rub the foam in evenly with a damp cloth .  

 

 

3 . Wipe with a clean and lightly dampened cloth .  

 

 

4 . Vacuum clean when dry . 

•  

 

Artificial leather has to be washed with soapy water or alternatively wiped down with an alcohol solution, e .g . 
disinfectant .

•  Leather upholstery requires a little extra maintenance:
 

 

- Spills must be wiped up immediately with a damp cloth; never use strong cleaning agents .

 

 

- Prevent upholstery from coming into contact with personal care products, such as make-up, hair gel, etc .

 

 

- Do not allow pets on leather furniture, as their claws may scratch the leather .

 

 

- Avoid direct and prolonged exposure to sunlight, as this can cause the leather to fade over time .

•  For functional reasons, seats, backrests and other padded parts are not made from impermeable materials . Padded 

parts should be replaced during reconditioning for hygienic reasons .

•  The electric lifting mechanism should be checked regularly for dust, dirt and stability: Raise the seat to its highest 

position . Clean with a cloth . Do not use any water or solvents . Then lubricate the cylinder using a thin layer of Teflon or 
silicone-based grease . 

•  The user or their assistant should remove dust, wipe clean and dry off the padded parts on the chair in accordance 

with the instructions above to the best of their ability and as needed . If this is not done satisfactorily, the chair will need 
to be reconditioned in order to guarantee hygienic safety .

GUIDELINES FOR INDIVIDUAL ADAPTATION OF MERCADO MEDIC AB’S PRODUCTS

Adjustments may be made only by staff who have completed Mercado Medic AB's training for service and reconditioning. 

Parts that are on the list of current combination agreements at

 www.mercado.se/mercado-dokument 

can be fitted while 

retaining Mercado Medic AB’s CE marking. If a desired item that is not on the list of currentcombination agreements is 

fitted, the customer’s authorised personnel must contact Mercado Medic AB for written approval. 
Parts to be evaluated must be sent physically to Mercado Medic AB, either by the customer or the supplier of the part in 

question. Mercado Medic AB will then contact the supplier of the part in question; if a combination agreement is deemed 

to be of interest, Mercado Medic AB performs a risk analysis on the part. Once the risk analysis is complete, the customer 

receives a written opinion.
Chairs that have been modified according to the following must be verified by Mercado Medic AB for Mercado Medic AB 

to keep the product liability.
 

•  Padded parts such as seats, backrests, armrests, side supports, trunk supports and neck supports can be adapted as long 

as the existing external dimensions of the product are not exceeded. 

 

• The centre of gravity over lifting devices must be maintained/centred for optimum function.

 

• Padded parts must be able to meet the applicable ignition requirements and other environmental requirements.

 

•  Surfaces that are loaded with significant vertical forces must not fall outside the area (base) that is formed by the 

points of the castor centres.

If these guidelines are met, Mercado Medic AB retains the product liability for its product.
Products that are specially modified by the health care services outside Mercado Medic AB’s directive, where the health 

care services also take over the product liability, can be restored to their original condition. This must be carried out by an 

authorised technician approved by Mercado Medic AB. Mercado Medic AB then takes back product liability in accordance 

with the CE marking 93/42 EEC; Medical Devices Directive MDD.
If you have any questions regarding adaptations/special adaptations, contact Ronny Fogelqvist:  

Tel. 

+46 (0)708 27 96 14 

E-mail 

ronny.fogelqvist@mercado.se

Summary of Contents for REAL 9500

Page 1: ...01 1 2 All textiles used in the chair have been tested and approved in accordance with EN 1021 1 and EN 1021 2 Mercado Medic AB is certified to ISO 9001 ISO 14001 and ISO 13485 and complies with appli...

Page 2: ...ENTS FAMILIARISE YOURSELF WITH YOUR REAL 9500 9600 EL PAGE 3 IMPORTANT INFORMATION CLASS PAGE 3 EXPECTED SERVICE LIFE PAGE 4 USER MANUAL PAGE 5 INDIVIDUAL ADAPTATION PAGE 8 CLEANING CARE PAGE 8 RECOND...

Page 3: ...before use in order to ensure that it can be used safely Repairs and other technical measures may only be carried out by personnel authorised by Mercado Medic AB REAL 9500 9600 EL is delivered as stan...

Page 4: ...o Medic AB has no control over how the product has been used and wear and tear The overall assessment of the Product should be carried out by the healthcare organisation if the product is prescribed a...

Page 5: ...e spring but ton clip locks and the back recliner cannot be pulled out The Comfort back mechanism is available in a low and high design illustrated chairs have a low back The back mechanism has separa...

Page 6: ...ing the red button 3 It has a holding circuit and only re quires a short press to activate the braking function To brake the chair press button 3 again SEAT TILT The gas spring tilt is controlled by a...

Page 7: ...or previously delivered updated chairs PLEASE NOTE It is particularly important to charge the battery on chairs with electric brakes electric tilt mechanisms and electric backs because these function...

Page 8: ...rvice and reconditioning Parts that are on the list of current combination agreements at www mercado se mercado dokument can be fitted while retaining Mercado Medic AB s CE marking If a desired item t...

Page 9: ...ion Do not use solvents bleach polishes synthetic detergents polishing waxes or sprays on the chair 1 3 Connectors attachment Check that cables and connectors are intact and properly secured Make sure...

Page 10: ...make sure that moving parts are working correctly 7 2 Attachment tightening Check that all screws knobs and wheels lock properly and that the spring button clips are working correctly 7 3 Plastic plug...

Page 11: ...20 07315 UK 02 11...

Page 12: ...ing Postal address Box 1074 SE 181 22 Liding Switchboard is open Mon Fri 08 00 16 30 CET CEST Tel 46 0 8 555 143 00 Fax 46 0 8 555 143 99 E mail info mercado se Service and technical support PO Box 10...