background image

2

2

30mm 

screw

P 4

For assistance please contact customer care on: 01636 880514

Mercia Garden Products Limited, 

Sutton On Trent, 

Newark, 

Nottinghamshire, 

NG23 6QN

www.merciagardenproducts.co.uk

Please retain product label and instructions for future reference

             

Pre drill 

hole

Step 4

 

Assembly of the Door Panel (

No. 2

) and 

Door (

No.8

).

Place the Door Panel (

No. 2

) on a flat level 

surface and place the Door (

No. 8

) as shown.

Fix the 3 Hinges (

No. 29

) to the door 

framing with 3x30mm black screws.

The door can be hung from either side 

to suit your needs.

It is important that the door is placed 

central in the space provided. 

 

Fix the Hinges (

No. 29

) to the  Door panel 

(

No. 2

) using 4x30mm black screws.

21x30mm black screws.  

Step 5

 

Place the Bunk Floor  (

No. 6

) onto the

horizontal framing of the Back Panel 

(

No. 3

) and flush with the horizontal 

framing of the Tall Window panel (

No. 5

).

Fix into position using 7x70mm screws as

shown. 

 

7x70mm screws.  

Pre drill 

hole

70mm 

screw

Pre drill 

hole

50mm 

screw

Step 6

 

Fix the back of the Door Panel (

No. 2

) against

 the sides of the Tall and Short Window Panels 

(

No. 4 

&

 No. 5

). Fix with 6x50mm screws 

internally. 

Do not secure the building to the Floor 

until the Roof is fitted.

6x50mm screws.  

Step 7

 

Fix the Bunk Floor (

No. 6

) onto the

horizontal framing of the Door Panel (

No. 2

as shown.

Fix into position using 3x70mm screws as

shown. 

 

3x70mm screws.  

Pre drill 

hole

70mm 

screw

8

29

7

2

6

Summary of Contents for 02BRAM0806-V3-PEFC

Page 1: ...in swelling of the wood panels may occur Warping of the wood may also occur during excessive dry spells due to an interior moisture loss Unfortunately these processes cannot be avoided but can be helped It is suggested that the outdoor building is sprayed with water during extended periods of warm sunshine and sheltered as much as possible during rain or snow Our buildings are pre treated with a w...

Page 2: ... V3D Window Box AI 02BRAM0806 V3WB Window Shutters AI 02BRAM0806 V3WS QTY x2 QTY x3 2x Fascia 12x95x1960mm SR1295 1960mm 2x Fascia 12x95x1040mm SR1295 1040mm 4x Fascia Blocks 27x44x423mm F2744 423mm Railing Upright 27x44x1060mm F2744 1060mm 3x Roof Bearer 27x44x1665mm F2744 1665mm 2x Roof Eave 28x28x2200mm F2828 2200mm 2x Cover Trim A 12x56x1680mm S1256 1680mm 2x Cover Trim B 12x56x2016mm S1256 20...

Page 3: ...ix the side of the Short Window Panel No 4 against the back of the Back Panel No 3 Do not secure the building to the Floor until the Roof is fitted 3x50mm screws Step 3 Fix the side of the Tall Window Panel No 5 against the back of the Back Panel No 3 Do not secure the building to the Floor until the Roof is fitted 3x50mm screws Pre drill hole 50mm screw Step 1 To fix the Windows No 10 No 13 into ...

Page 4: ...ews 21x30mm black screws Step 5 Place the Bunk Floor No 6 onto the horizontal framing of the Back Panel No 3 and flush with the horizontal framing of the Tall Window panel No 5 Fix into position using 7x70mm screws as shown 7x70mm screws Pre drill hole 70mm screw Pre drill hole 50mm screw Step 6 Fix the back of the Door Panel No 2 against the sides of the Tall and Short Window Panels No 4 No 5 Fix...

Page 5: ... No 30 as shown below Fix into position using 36x30mm screws 36x30mm screws Step 10 To make the Safety Rail secure fix the Railing Upright No 17 into place so that it is flush with the side of the the Bunk Floor and flush with the Roof Bearer Fix into position as shown using 3x40mm screws 3x40mm screws Step 11 Fix your ladder together as shown using 4x50mm per Ladder Step No 22 No 23 No 24 16x50mm...

Page 6: ...x40mm screws starting from the top your building Make sure to screw into the framing Make sure the rear of the building is flush with the Roof OSB This will ensure your roof is straight 4x30mm screws 26x40mm screws Step 14 Fix the Fascia Blocks No 16 to the Roof OSB No 7 using 3x30mm screws per block Use 2x40mm screws to fix the blocks to eachother 4x40mm screws 12x30mm screws Step 15 Fix the Cove...

Page 7: ...rvals Use a final fourth peice of felt along the Apex of the building as shown 110x Felt Tacks Step 17 Fix the Fascias No 14 No 15 using 3x40mm screws per board Fix the Finials 2xNo 25 with 2x40mm screws per Finial as shown 16x 40mm screws 2 4 3 1 Step 18 Fix the Window Crosses No 26 into position using 4x20mm screws per Window Cross 32x 20mm screws 14 15 14 15 25 26 Pre drill hole 40mm screw Pre ...

Page 8: ...d instructions for future reference Step 19 Fix the Window Shutters No 12 and Window Box No 11 in position screwing from inside through the cladding as shown 12x 30mm screws Step 20 Fix the Chrome Handle No 28 to the Door No 8 using 4x30mm black screws Fix the Door Stop No 27 to the inside of the door using 3x20mm screws as shown 4x 30mm black screws 3x20mm screws 12 11 28 27 Pre drill hole 20mm s...

Page 9: ......

Reviews: