background image

17

17

18

18

17

17

P 7

19 

Please retain product label and instructions for future reference

16

16

16

16 

16

16

16

Step 18

Attach the cover trims to each

corner of the building and 

across each joint between

the fixed panels, using 3x30mm

screws per cover trim.

21x30mm Screws

Pre drill 

hole

30mm 

screw

Step 19

Fix the fascias and finials

to the front and back of

the building using 

12x40mm screws.

12x40mm Screws

Pre drill 

hole

40mm 

screw

Step 20

Fix the rain guards above each

window, securing in place

using 2x50mm screws per

guard, ensuring to screw

through the framing.  

4x50mm Screws

Pre drill 

hole

40mm 

screw

16

Step 21

Attach the two turn buttons to the

slave door at the top and bottom 

using 2x30mm black screws.

2x30mm Black Screws

*These turn buttons help to keep

your doors straight during high &

low levels of moisture content in

the air.

30mm 

screw

Pre drill 

hole

Summary of Contents for 03VER1008-V2

Page 1: ...tended periods of rain swelling of the wood panels may occur Warping of the wood may also occur during excessive dry spells due to an interior moisture loss Unfortunately these processes cannot be avo...

Page 2: ...anel Right AI 03VERWPR2310X2007 V1 Window Panel Left AI 03VERWPR2310X2007 V1 Back Panel QTY 2 AI 03VERBP1490X2015 V1 Gable Top QTY 2 AI 03VERGT2310X546 V1 Floor QTY 2 AI 01TAGF2360X1487 V1 Roof Sheet...

Page 3: ...re fixing to the door Fix the door handles to the outside of the master and slave door using the 35mm bolts provided 36x10mm Screws 4x25mm Screws 4x35mm Bolts Pre drill hole 10mm screw 25mm screw 24 S...

Page 4: ...roof is fitted 9x50mm Screws Pre drill hole 50mm screw 5 4 Step 8 Place the gable tops onto the window panels ensuring the boards interlock Secure in place using 4x50mm screws per gable top screwing...

Page 5: ...s into the ridge bar with 1x50mm screw per bar screwing at an angle as shown in the illustration Ensure to stagger the screws so as not to hit one screw with another 2x50mm Screws Pre drill hole 50mm...

Page 6: ...o the building securing in place with 11x30mm screws Fix the first eaves frame onto the roof sheet seceuring with 3x30mm screws Fix the remaining roof sheets to the building using 11x30mm screws per s...

Page 7: ...s to the front and back of the building using 12x40mm screws 12x40mm Screws Pre drill hole 40mm screw Step 20 Fix the rain guards above each window securing in place using 2x50mm screws per guard ensu...

Page 8: ...piece of framing should fit tightly between the two side panels Step 23 Screw through the side panel exter nally in line with the 2 x 1 framing using 2 x 70mm screw in either side to secure the frami...

Page 9: ...ommended that after the construction treatment and the removal of the protective window cover that sealant is used to keep the building weather tight 30mm screw 28 28 Step 24 Attach a strip to the hin...

Reviews: